Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T11CM00658
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/04/2011 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 03/04/2011 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 03/09/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. This project is governed by the 2006 IBC which has as the ICC (ANSI 117.1 2003 Edition) as the compliant accessibility code. a. Please change all details and references from ADA to ICC (ANSI 117.1, 2003 Edition). b. Please review all accessibility design details and change them to be in compliance with the ICC (ANSI 117.1, 2003 Edition). c. An accessible compliant review for ADA Accessible Standards may be conducted upon an approved appeal to the building official, Mr. Ron Boose. If so desired, please complete a building official appeal and submit for review and approval. A fee of $132.00 is required for processing. 2. Generic details are not acceptable. Sheet nos. ADA1.0 and ADA 1.1 are mostly code copied details that that no relevance to the actual design of the accessibility elements of this project. a. Please delete all details not relevant to this project. b. Please provide all accessible requirements (dimensions and accessories) on the actual toilet design elevations and floor plan. 3. Please include the vertical grad bar in all required toilet elevations: A/A8.2, 1, 2, 6, and 7/A8.2. 4. Existing building background on all floor plans are drafted too light. Please increase the line weight for the existinmg conditions for all floor plans and resubmit. END OF REVIEW |
| 03/09/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 03/10/2011 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 03/23/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 03/23/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Provide complete plumbing plans for the new work, including waste and vent isometrics of the new work. Reference: Section 103.2.3, UPC 2006. |
| 03/23/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 03/24/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T11CM00658 3930 E 22nd St Electrical plans denied for the following: 1. Review all lettering and numbering , min 3/32" 2. Identify circuits on power and lighting plans. 3. Show location of Pnl B. 4. Date Load Calculation Report. Ray T Majuta PDSD, City of Tucson Elect Pln CK 3/28/11 Ray.majuta@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/21/2011 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 06/21/2011 | SUE REEVES | REJECT SHELF | Completed |