Permit Number: T11CM00657
Parcel: 11107002A

Address:
3455 E GRANT RD

Review Status: Completed

Review Details: SITE

Permit Number - T11CM00657
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/04/2011 MARTIN BROWN FIRE REVIEW Approved
03/04/2011 RBROWN1 ADA REVIEW Passed
03/07/2011 PAUL MACHADO ENGINEERING REVIEW Denied To: Daniel J. Marks DATE: March 11, 2011
2643 4th Ave
San Diego, CA., 92103

Subject: Taco Bell, 3455 E. Grant Rd.
Site plan T11CM00657 (First Review)
T13S, R14E, Section 33

RESUBMITTAL REQUIRED: Site Plan.

The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. It appears that the site plan is not depicting the actual site conditions. Although the revisions are considered minor for engineering, a correctly drawn site shall be included in the submittal. The following items are listed from the City of Tucson Development Standards and shall be shown on the site plan.
3. 2-02.2.0 - SITE PLAN CONTENT AND SPECIFICATIONS:
2.1 Site Plan.
A. The site plan is drawn at a standard engineering scale no larger than l" = 60' on a
sheet(s) no larger than 30" by 42" (24" by 36" recommended) and includes, but is not
limited to, the following:
1. North arrow and scale.
2. Property description.
3. Project address.
4. Location map.
5. Lot dimensions and bearings.
6. All existing and proposed buildings and structures, including location, size, height,
overhangs, canopies, and use.
10. Existing and future sight visibility triangles.
11. Points of egress and ingress including locations and width of driveways and
parking area access lanes (PAALs).
18. Street names.
19. Dimensioned right-of-way, including any applicable Major Streets and Routes
(MS&R) Plan right-of-way.
21. Dimensions from street monument lines to existing and proposed curbs,
sidewalks, driveways, and utility lines.
29. Site plan number (T11CM00657).

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson - Planning and Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/3455 E. Grant Rd. Site
03/09/2011 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Taco Bell - 3455 E. Grant Road
T11CM00657
Site Plan (1st Review)

TRANSMITTAL DATE: March 9, 2011

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1) This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC). This project will be reviewed for full code compliance for any areas of change once a site plan is provided that correctly reflects what is currently on site and what changes are proposed.

2) As there appears to be changes proposed to curbing, number of parking spaces, loading spaces location, etc. provide a site plan that meets all requirements of D.S. 2-02.0. Clearly identify all areas of change or modification.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\2011\t11cm00657

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan.
03/15/2011 RONALD BROWN H/C SITE REVIEW Denied SHEET C2
1. Signage:
a. Relocate the position of both signs to a point just inside the curb/concrete walk aare, not in the asphaltic pavement.
2. Please reference select large scale details that are relevant to this parking layout.
SHEETS ADA1.0 AND 1.1
3. Please delete all details shown on these two sheets that are not relative to the design of this project.
4. Please provide one large scale detail of the accessible parking layout with all requirements shown on this one detail. Three details are not necessary.
END OF REVIEW
03/21/2011 ANDREW CONNOR LANDSCAPE REVIEW Denied All plant material used for landscaping shall be selected from the Drought Tolerant Plant http://www.azwater.gov/azdwr/WaterManagement/AMAs/documents/2007_Plant_List_apha_botanical.pdf.
Pennisetum alopecuroides 'Hamlin' [Dwarf Fountain Grass] is not included on list and is on the Arizona Wildlands Invasive Plant List. All Arborvitae species are not included on the list. Revise sheet L1.0 to include appropriate plant materials.
03/21/2011 ANDREW CONNOR NPPO REVIEW Approved
03/23/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the site drawing to include the following information:
a. the location and size of the water meter
b. the location of the main water lines and fire hydrants
c. the location of the gas meter (if one exists or is planned)
d. the location and size of the public sanitary sewer
e. the location of the building connection to the public sewer
f. the location, invert, and rim elevation of the upstream and downstream manholes or cleanouts
g. the first floor elevation for the building
Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/25/2011 SUE REEVES OUT TO CUSTOMER Completed
07/25/2011 SUE REEVES REJECT SHELF Completed