Permit Number: T11CM00518
Parcel: 13101053B

Address:
1255 S SWAN RD

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T11CM00518
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/04/2012 RONALD BROWN HC SITE REVIEW Denied 1. At detail 8/S-1:
a. Detectable warning strips are not required at this location.
b. The sidewalk run is not drawn to scale. A 6" curb will require a 6' run which will encroach on the entrance to the front door and squeeze the access width at the corner. A better solution is to reverse the parking space with the parking aisle, provide a 4' wide landing with two 1:12 ramps on both sides and eliminate the sidewalk scupper for drainage. See sketch attached to drawing.
2. Insure all accessible routes comply with ICC A117.1, Section 403.3; 5% max running slope and 2% max cross slope.

Corections may be approved on an over-the-counter walkthrough.
END OF REVIEW
09/05/2012 ANDREW CONNOR LANDSCAPE REVIEW Approv-Cond Demolition permit for the removal of the billboard must be issued prior full permit approval D.S.
2-2.2.2.A.5.
09/10/2012 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Borst Automotive
T11CM00518
Site Plan (5th Review)

TRANSMITTAL DATE: September 10, 2012

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC). This project has been reviewed for full code compliance due to building area expansion exceeding 25%.

2. This comment has not been addressed. A demolition permit for the removal of the billboard must be issued prior to approval of this site plan. D.S. 2-02.2.1.A.12 Per LUC Section 3.3.3.9 Parking spaces shall not be located under, or within five (5) feet of, a vertical line intersecting the ground and any structural element extending from a billboard, including, but not limited to, overhangs, cantilevered beams, and elevated walkways. That said the proposed vehicle parking spaces located just to the north of the billboard do not meet this code requirement.. Board of Adjustment for Variance required.

3. The provided parking agreement does not meet the minimum requirements, see attached OFF-SITE, OFF-STREET VEHICLE PARKING INFORMATION PACKET. Revise the agreement per this document.

4. This comment has not been addressed. A demolition permit for the removal of the billboard must be issued prior to approval of this site plan. D.S. 2-02.2.2.A.5 Per LUC Section 3.4.5 one (1) 12' x 35' loading space is required for the billboard, zero (0) are provided. A Board of Adjustment for Variance is required.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\2011\t11cm00518

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan, Approved site plan for 1335 S. Swan, Recorded parking agreement.