Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T11CM00518
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/13/2012 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Borst Automotive T11CM00518 Site Plan (4th Review) TRANSMITTAL DATE: August 13, 2012 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC). This project has been reviewed for full code compliance due to building area expansion exceeding 25%. 2. A demolition permit for the removal of the billboard must be issued prior to approval of this site plan. D.S. 2-02.2.1.A.12 Per LUC Section 3.3.3.9 Parking spaces shall not be located under, or within five (5) feet of, a vertical line intersecting the ground and any structural element extending from a billboard, including, but not limited to, overhangs, cantilevered beams, and elevated walkways. That said the proposed vehicle parking spaces located just to the north of the billboard do not meet this code requirement.. Board of Adjustment for Variance required. 3. Provide a copy of the last approved site plan for 1335 S. Swan that shows that there are three (3) vehicle parking spaces over and above the required number for the existing use on site. Provide a copy of the recorded parking agreement with your next submittal. Swan. D.S. 2-02.2.2.A.4 Automotive Service and Repair - Major per LUC Sec. 3.3.4 requires vehicle parking spaces to be provided at 1 spaces per 300 Sq. ft. of GFA. This site has 5528 Sq. ft. of gross floor area therefore requiring 18 vehicle parking spaces. The proposed number of vehicle parking spaces is 15. A Board of Adjustment for Variance is required based on LUC Section 3.3.4.2 to reduce the number of vehicle parking spaces by 3. 4. A demolition permit for the removal of the billboard must be issued prior to approval of this site plan. D.S. 2-02.2.2.A.5 Per LUC Section 3.4.5 one (1) 12' x 35' loading space is required for the billboard, zero (0) are provided. A Board of Adjustment for Variance is required. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\2011\t11cm00518 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan, Approved site plan for 1335 S. Swan, Recorded parking agreement. |
| 08/13/2012 | RONALD BROWN | HC SITE | REVIEW | Denied | Provide accessible route to front entrance |
| 08/14/2012 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | On a project with an existing or a proposed new billboard on site, the loading space required for the billboard must be located immediately adjacent to the billboard and outside the area defined by a vertical line intersecting the ground and any structural element extending from the billboard, including, but not limited to, overhangs, cantilevered beams, and elevated walkways (Variance comment). Demolition permit for the removal of the billboard must be issued prior to approval of site or landscape plans. D.S. 2-2.2.2.A.5. |