Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T11CM00423
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/08/2011 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 02/08/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Condensate drains may not terminate over a roof. The condensate may drain over a roof drain if the roof drain terminates at or above grade in an area capable of absorbing the condensate flow without surface drainage. Reference: Section 307.2.1, IMC 2006, as amended by the City of Tucson. 2. Show the exhaust for the restrooms along with the balancing data for the exhaust. |
| 02/08/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 02/08/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 02/08/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. Several sheets have font sizes that are less than COT standard of 3/32" minimum for both lower and upper case. Please revise and resubmit. 2. Please provide a letter of deferred submittals to the building offical, Mr. Ron boose fo additional fee assessment. a. Please insure that all necessary structural details and calculations for the new RCMU wall lintel are including including any required new columns and foundations. 3. Please provide ANSI required vertical grab bar for both toilet rooms. 4. Stairs risers of 8" shown for both sets of stairs are not code compliant. Please revise and resubmit. 5. Please reference lateral bracing details, 2,3/A0.0 from detail 2/A5.0. END OF REVIEW |
| 02/08/2011 | BEV HESTER | ENGINEERING | REVIEW | Approved | |
| 02/08/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Note: this review is based on the 2006 Uniform Plumbing Code, as adopted by the City of Tucson. 1. Specify the backflow device needed for the boiler water connection. reference: section 503, UPC 2006. 2. Backflow devices shall be located a maximum of 5'-0" above the finished floor or a working platform. Reference: Section 603.3.4, UPC 2006. 3. Show how the water temperature for the public lavatories will be limited to 110 degrees Fahrenheit or less. Reference: Section 413.1, UPC 2006 and Section 504.3, IECC 2006. 4. Show the termination of the T&P relief piping. Reference: Section 608.5, UPC 2006. 5. Provide upper terminal cleanouts on horizontal drainage pipes exceeding 5 feet in length (horizontal drain lines serving sinks require cleanouts regardless of length). Reference: Section 707.4, UPC 2006. 6. Provide cleanouts sized per Section 707.11, UPC 2006. |
| 02/08/2011 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 02/08/2011 | RONALD BROWN | ADA | REVIEW | Passed | Not a COT owned or operated property |
| 02/08/2011 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 02/22/2011 | CPIERCE1 | WWM | REVIEW | Needs Review |