Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T11CM00390
Parcel: 105102440

Address:
495 E WETMORE RD

Review Status: Active

Review Details: SITE

Permit Number - T11CM00390
Review Name: SITE
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
03/04/2011 MARTIN BROWN FIRE REVIEW Approved
03/07/2011 PAUL MACHADO ENGINEERING REVIEW Denied To: Daniel J. Marks DATE: March 11, 2011
2643 4th Ave
San Diego, CA., 92103

Subject: Taco Bell, 495 E. Wetmore Rd.
Site plan T11CM00390 (First Review)
T13S, R13E, Section 24

RESUBMITTAL REQUIRED: Site Plan.

The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. It appears that the site plan is not depicting the actual site conditions. Although the revisions are considered minor for engineering, a correctly drawn site shall be included in the submittal. The following items are listed from the City of Tucson Development Standards and shall be shown on the site plan.
3. 2-02.2.0 - SITE PLAN CONTENT AND SPECIFICATIONS:
2.1 Site Plan.
A. The site plan is drawn at a standard engineering scale no larger than l" = 60' on a
sheet(s) no larger than 30" by 42" (24" by 36" recommended) and includes, but is not
limited to, the following:
1. North arrow and scale.
2. Property description.
3. Project address.
4. Location map.
5. Lot dimensions and bearings.
6. All existing and proposed buildings and structures, including location, size, height,
overhangs, canopies, and use.
10. Existing and future sight visibility triangles.
11. Points of egress and ingress including locations and width of driveways and
parking area access lanes (PAALs).
18. Street names.
19. Dimensioned right-of-way, including any applicable Major Streets and Routes
(MS&R) Plan right-of-way.
21. Dimensions from street monument lines to existing and proposed curbs,
sidewalks, driveways, and utility lines.
29. Site plan number (T11CM00390).

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson - Planning and Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/495 E. Wetmore Rd. Site
03/11/2011 RONALD BROWN H/C SITE REVIEW Approved
03/11/2011 TERRY STEVENS ZONING REVIEW Approved
03/14/2011 ANDREW CONNOR LANDSCAPE REVIEW Passed
03/15/2011 ANDREW CONNOR NPPO REVIEW Passed
03/23/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the site drawing to include the following information:
a. the location and size of the water meter
b. the location of the main water lines and fire hydrants
c. the location of the gas meter (if one exists or is planned)
d. the location and size of the public sanitary sewer
e. the location of the building connection to the public sewer
f. the location, invert, and rim elevation of the upstream and downstream manholes or cleanouts
g. the first floor elevation for the building
Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006.