| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/04/2011 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | P&DS TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T11CM00337 2400 East Adams Street Addition to SFR and garage addition to detached sleeping quarters TRANSMITTAL: February 4, 2011 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO). This Site requires a DDO for the side-street setback along the west property line and an interior lot line setback along the east property line. This site is in the R-1 Zone (LUC Section 2.3.4.2.A.1). The Development Designator is "G" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator AA (LUC Section 3.2.6.4). The minimum setback to a side street in a residential zone is ten (10) feet (LUC Section 3.2.6.5.A). The propose setback is eight (8) feet. The minimum setback to the east property line is the greater of six feet or two-thirds the height of the structure's wall facing the property line. The height of the garage addition's wall facing the east property line is fifteen (15) feet, eleven (11) inches. The minimum setback to the east property line is ten (10) feet, eleven (11) inches. The proposed setback is six (6) feet. |
| 02/04/2011 | MICHAEL ST. PAUL | NPPO | REVIEW | Passed | |
| 03/22/2011 | DROBEY1 | ENGINEERING | REVIEW | Needs Review | |
| 03/22/2011 | DROBEY1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review |