Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T11CM00085
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/16/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 02/23/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 02/24/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. At sheet T1.1, "Building Code Information", delete the reference to "Arizonians with Diasbilities Act" and reference the 2006 IBC, Chapter 11 and ICC (ANSI 117.1, 2003 Edition). 2. At sheet A1.5: a. Please provide a note reference to the 2006 IBC, Chapter 11 and ICC (ANSI 117.1, 2003 Edition) for all accessibility requirements. b. At detail nos. 1, 8 and 9 please relocate the toilet dispenser and provide a vertical grab bar as per the 2006 IBC, ICC (ANSI117.1, 2003 Edition), Section 604.5.1. c. At detail nos. 1, 3 and 4, please provide a vertical grab bar as per the 2006 IBC, ICC (ANSI117.1, 2003 Edition), Section 604.5.1. END OF REVIEW |
| 03/01/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Comment not resolved; correct the font size in detail 4/P3.1. [Revise the font size used on the drawings to a minimum of 3/32-inch (all upper case). Reference: Section 106.1.1, IBC 2006.] 2. Comment not resolved; detail 4/P3.1 still shows an incorrect pipe size. [Correct and coordinate details 3/P3.1 and 4/P3.1 with regard to the sizes of the gas piping. Reference: Sections 103.2.3 and 1217.1, UPC 2006.] 3. Comment not resolved. Show how and where the correctly-sized cleanouts are to be provided for the 4" drain lines in the cooking and prep areas. [Provide information to show that the cleanouts have been sized per Section 707.11, UPC 2006 (see the 4" drain lines in the cooking area and the prep area).] |
| 03/02/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 03/02/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Comment not resolved; for a combined capacity of 24 tons of air conditioning, a 1-1/4" condensate drain is required. [Show the size, routing, and termination of the condensate drains from the new rooftop units. Reference: Section 307.2, IMC 2006 and Section 814.0, UPC 2006.] 2. Comment not resolved. The occupant load used for calculating the minimum required ventilation for a fast food/cafeteria, based on Table 403.3, IMC 2006 is 100 persons per 1,000 square feet. Reference: Section 403.3, IMC 2006. [Provide calculations demonstrating adequate ventilation. Reference: Section 403.3, IMC 2006, as amended by the City of Tucson.] 3. Comment not resolved. With a flow rate of 1233 CFM, the 12" x 14" exhaust duct for KH-1 will have an air velocity of only 1056 feet per minute; far lower than the required minimum velocity of 1500 feet per minute. [Show the location of the grease exhaust duct for the griddle hood, KH-1, and indicate the size of the duct. Reference: Sections 106.3.1 and 506.3.4, IMC 2006, as amended by the City of Tucson.] 4. Comment not resolved. With a flow rate of 800 CFM, the 10" x 10" exhaust duct for KH-2 will have an air velocity of only 1152 feet per minute; far lower than the required minimum velocity of 1500 feet per minute. [Revise the size of the grease duct for the fryer hood, KH-2, to provide a minimum velocity of 1500 feet per minute (the mechanical floor plan shows a 14" x 12" duct and an exhaust flow rate of only 800 CFM). Reference: Section 506.3.4, IMC 2006, as amended by the City of Tucson.] 5. Comment not resolved. To comply with the requirements of Section 507.2.1.1, IMC 2006, the exhaust fan for the hood (and of course, the make-up air source) must start automatically with the commencement of cooking operations; the electrical schematic does not appear to provide that capability. [Provide information to show that the operation of the Type I hoods and the hood exhaust fans comply with Section 507.2.1.1, IMC 2006.] |
| 03/04/2011 | DAVID RIVERA | ZONING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/04/2011 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 03/04/2011 | DELMA ROBEY | REJECT SHELF | Completed |