Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: OTHER
Permit Number - T11BU01713
Review Name: OTHER
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/27/2011 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 12/27/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | December 27, 2011 FLOODPLAIN USE PERMIT NO.: T11OT02337 ADDRESS: 3319 E Bermuda St, Tucson Arizona 85716 PROPERTY OWNER: Michael Herbert 3319 E Bermuda St, Tucson Arizona 85716 The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Christmas Avenue Wash delineation, specifically described as: Fruitvale E50' of S150' of Lot 4 BLK 7 For the purpose of constructing 4 120 AQFT Sheds. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 9 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the Tuff Shed, or, if there is any further disturbance within the floodplain and W.A.S.H. overlay other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of a shed within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) All work shall conform to the approved Details and General site plan sheets for the construction of the 4 120 SQFT Sheds, which are made part of this permit. The existing block wall provides a flow shadow for the shed and since the shed is used solely for storage it is not required to be elevated however venting of the shed is required. 4) For every square foot of enclosed space there must be a minimum 2 vents with the same square inches of openings. Wet floodproofing of the structure is required to prevent water damage to the structure and potential collapse. 5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T11OT02337 FOR INFORMATION PLEASE CALL 791-5550." 6) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 7) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 8) See the associated activity T11BU01713 9) This permit is specific to the improvements for 3319 E Bermuda Street as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Tim Connally ADDRESS: 84 W Grant Rd Tucson, AZ 85705 PHONE: 520-N/A CONTRACTOR: Michael Herbert ADDRESS: 3319 E Bermuda Street Tucson, AZ 85716 PHONE: 520-N/A (EXPIRATION DATE) Month: _12 Day: 27 Year: 2012 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/27/2011 | CPIERCE1 | OUT TO CUSTOMER | Completed |