Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD - BLDG30days
Permit Number - T11BU01335
Review Name: BILLBOARD - BLDG30days
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2013 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | BRC Comments Below are comments for the authorized repair submittal for COT ID# 185 at 803 South 6th Avenue (T12BU01335). Sheet 1 of 2 1. Correct the APN for the subject parcel on the aerial photograph overlay. 2. If the bolts attaching stringers to rooftop structure are to be replaced, add Exhibit 9, Subsection 2(u) to Billboard Note #9. Sheet 2 of 2 1. In third bullet of Scope Work, provide depth of the panel sections (in addition to gauge). 2. Conform the note about light fixture removal from the site to that contained in the Site Plan (Sheet 1). 3. Provide top and front view detail of the stringer attachment to the rooftop structure (include cross-section dimensions of the structure uprights). 4. Clarify if bolts attaching stringers to rooftop structure are to be replaced, and if so add Exhibit 9, Subsection 2(u) to note below Scope of Work. 5. In appropriate view or elevation, specify the horizontal spacing dimensions between the vertical face edges and outer uprights and between the respective uprights. 6. Provide light mounting detail. 7. Provide standard descriptions of existing lamp and ballast and missing lighting notes (re point of disconnect and language in Billboard Note #11 on Sheet 1). 8. In Title Block, revise sheet reference to 2 of 2. 1/10/13 Below are revised comments for the authorized repair resubmittal for COT ID# 185 at 803 South 6th Avenue (T11BU01335). The comments provided on 1/7/13 were based on the original submittal having been provided for review rather than the resubmittal. Sheet 1 of 2 No comments. Sheet 2 of 2 1. Conform the note about light fixture removal from the site to that contained in the Site Plan (Sheet 1). 2. Provide top and front view detail of the stringer attachment to the rooftop structure uprights, including cross-section dimensions of the uprights being attached to (in this instance, adding a text note that specifies the cross-section dimensions and thickness of the uprights is sufficient). 3. Revise Scope of Work or add note to Stringer/Face Mounting Detail to clarify that the bolts attaching stringers to rooftop structure uprights are to be removed and reinstalled and the total number of connections to be made. 4. In appropriate view or elevation, specify the horizontal spacing dimensions between the vertical face edges and outer uprights. 5. Provide Professional Engineer's seal and signature (per Exhibit 12, Section 1(b)(4)). |
| 12/26/2012 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/02/2013 | GERARDO BONILLA | REJECT SHELF | Completed |