Permit Number: T11BU00179
Parcel: 136242320

Address:
3152 S KOLB RD

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T11BU00179
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/07/2011 DAVID RIVERA ZONING REVIEW Denied FROM: David Rivera
Principal Planner

Project:
T11CM00179
3152 S Kold Road (R-2 )
Four Car Carport
Single Family Home Development


COMMENTS: the following comments are relative to an application for a Board of Adjustment Variance for Carport Setback).

Owner / Applicant has constructed a Four Car Carport in the Front Yard of the property. The carport is setback 13'-7" from the street property line and 1' from back of the existing sidewalk. The carport is setback 0' from the east property line. A DDO is required for this setback as well.

The carport is a 20' x 34' structure and is detached at this time but the owner/applicant has been instructed that the carport must be attached to the principal structure.

The building setbacks from the front street is based on the LUC Section 3.2.6.5.2

2. Carports and Garages in Single-Family and Duplex Development. For carports, garages, or similar parking structures in single-family or duplex residential development on individual lots, a minimum setback shall be provided using either of the following alternatives. (See Illustration 3.2.6.5.B.2.)

a. A minimum setback of nineteen (19) feet from the back of sidewalk to allow sufficient space for a motor vehicle to be parked in front of the carport or garage, measured as follows.

1. Eighteen (18) feet (the length of a standard parking space) must be provided in front of
the carport or garage and measured so that the full eighteen (18) foot parking space is available for parking on-site.

2. The eighteen (18) foot parking space shall be no closer than one (1) foot from back of sidewalk of the street from which access is gained.

The carport has been constructed 13' x 7" from the post to the property line and 14'- 7" from the back of the sidewalk.

The carport has been constructed at 0' from the east property line.

Both carport structure setback should be processed through the Board of Adjustments.
02/07/2011 DAVID RIVERA NPPO REVIEW Denied
06/06/2011 PAUL MACHADO ENGINEERING REVIEW Approved
08/18/2011 CAGUILA1 BUILDING-RESIDENTIAL REVIEW Needs Review