Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: SIGN CODE APPEALS AND ADVISORY BOARD
Permit Number - T10SA00344
Review Name: SIGN CODE APPEALS AND ADVISORY BOARD
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2011 | SUE MONTES | IT TECH | REQUEST SET UP OF EQUIPMENT | Completed | |
| 01/03/2011 | SUE MONTES | DECISION | PREPARE SUMMARIES AND DECISION LETTERS | Completed | |
| 01/03/2011 | SUE MONTES | DECISION | EMAIL/MAIL DECISION LETTERS | Completed | |
| 11/15/2010 | SUE MONTES | START | APPLICATION ACCEPTED | Completed | |
| 11/16/2010 | DAVID RIVERA | ZONING | REVIEW | Passed | |
| 11/22/2010 | JOHN BEALL | COMMUNITY PLANNING | REVIEW | Approved | SUBJECT: Sign Code Advisory And Appeals Board Application CASE NUMBER: T10SA00344 [Appeal] CASE NAME: Tucson JCC CROSS REFERENCE: NEIGHBORHOOD PLAN: Jewish Community Campus PAD GATEWAY/SCENIC ROUTE: Scenic COMMENTS DUE BY: 11/29/10 ( X ) No Objection - Complies With Plan Policies ( ) Staff Submits the Following Previous Comments - See Below SUBJECT: Sign Code Advisory And Appeals Board Application CASE NUMBER: T10SA00344 CASE NAME: Tucson JCC CROSS REFERENCE: NEIGHBORHOOD PLAN: Jewish Community Campus PAD GATEWAY/SCENIC ROUTE: Scenic COMMENTS DUE BY: 9-24-10 ( X ) No Objection - Complies With Plan Policies ( ) Staff Submits the Following Comments - See Below The purpose of the Jewish Community Campus PAD is to encourage a comprehensively planned development that would enable over time expansion of the campus and allow for additional uses that will support existing development. While the JCC PAD calls out that signs will be in accordance with the City of Tucson Sign Code; there have numerous roadway projects in the area, i.e. Alvernon Bridge and River Road expansion. This roadway improvement opened up the southern boundary of the Campus to passing vehicular, bicycle, and pedestrian traffic. Alvernon Way is not a scenic route, and the proposed signage provides signage for the campus at its now exposed southern boundary, and can serve to guide vehicles, pedestrians, and bicyclists. The Scenic Route is concerned with the preservation of views and view sheds, scenic quality of the desert. Methods proposed to preserve foreground and distant views include setbacks, building orientation, and location of development in areas less visible from the roadway. The applicant is proposing to place a wall sign on the South elevation of the existing Tucson Jewish Community Center building that: · Faces Alvernon Way, a non-scenic arterial; · Setback from Alvernon Way by 270 feet; · Proposed signage will not be visible from River Road, a scenic route; · Appears to be Setback from River Road by over 500 feet; · Located on an existing building so there appears to be no new disturbance to views or view sheds. Staff has no objection to the proposed sign request as it appears to meet the intent of the scenic corridor for preserving views and view sheds, and meets the objective and goals of the JCC PAD encouraging comprehensively planned development. REVIEWER: JBeall DATE: 9/14/10 |
| 11/23/2010 | HEATHER THRALL | SIGNS | SIGN CODE REVIEW | Completed | |
| 11/23/2010 | SUE MONTES | LEGAL AD | PREPARE LEGAL AD | Completed | |
| 11/23/2010 | SUE MONTES | LEGAL AD | LEGAL AD TO PAPER, MAIL LEGAL AD | Completed | |
| 11/30/2010 | SUE MONTES | AGENDA | AGENDA TO BCC | Completed | |
| 11/30/2010 | SUE MONTES | FIELD TRIP | FIELD TRIP | Completed | |
| 12/07/2010 | SUE MONTES | REPORT | BEGIN STAFF REPORT | Completed | |
| 12/07/2010 | SUE MONTES | REPORT | STAFF REPORT TO ADMINISTRATOR | Completed | |
| 12/07/2010 | SUE MONTES | REPORT | DISTRIBUTE STAFF REPORT | Completed | |
| 12/07/2010 | SUE MONTES | REPORT | POWERPOINT PRESENTATION COMPLETE | Completed | |
| 12/07/2010 | SUE MONTES | REPORT | HEARING DATE | Completed | |
| 12/07/2010 | SUE MONTES | REPORT | HAVE IT UPLOAD PRESENTATION | Completed | |
| 12/14/2010 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Completed | TDOT-Traffic has no objections to the proposed sign. |
| 12/15/2010 | SUE MONTES | HEARING | SET HEARING DATE | Completed |