Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10OT01442
Parcel: 13303232C

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T10OT01442
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/01/2010 BIANCA RAMIREZ ENGINEERING REVIEW Approved July 1, 2010
FLOODPLAIN USE PERMIT # T10OT01442
PROJECT ADDRESS: 10024 E El Poso Trail
APPLICANT'S NAME: Louis Woofenden, Net Zero Solar
PROPERTY OWNER: Martin and Jane Rojas


This parcel lies in a FEMA Zone AE (100-year) map number 040076 C 2257K, effective February 8, 1999. Federal law requires that a flood insurance policy be obtained as a condition of a federally backed mortgage or loan that is secured by a building located within a SFHA. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:

PARCEL 133-09-232C; 10024 E El Poso Trail, Tucson, AZ 85749, POWDER HORN RANCH LOTS 10 & 11 (ABAND PROC 2403: 6546/813) (10645/293). In a portion of Township 14 South, Range 15 East, Section 2 for addition of photovoltaic system to conforming structure (Barn).

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and are bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit.

The following conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) The proposed addition is located within an FEMA Zone AE, as defined in The Floodplain and Erosion Hazard Management Ordinance, Chapter 26 of the Tucson Code (Ordinance).

4) All work shall conform to the approved details and general Site Plan, which are made part of this permit. Photovoltaic system located on rood of existing conforming residence. All electrical components will be installed at a minimum of 6' above highest existing adjacent natural grade.

5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T10OT01442 FOR INFORMATION PLEASE CALL 791-5550."

6) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.

7) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

8) Contractor will need to call for floodplain use permit inspections by Development Services Department Engineering Division Inspection Team (791-5550) prior to and after the installation of the prefabricated storage container.

9) See the associated activity T10CM01696.


This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of approval. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 7 Day: 1 Year: 2011

APPLICANT: Louis Woofenden, Net Zero Solar
ADDRESS: 101 W 5th Street, Tucson, Arizona 85705
PHONE: (520) 237-5040
OWNER: Martin and Jane Rojas
ADDRESS: 10024 E El Poso Trail, Tucson, Arizona 85749
PHONE: (520) 749-0799


SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/13/2010 CPIERCE1 OUT TO CUSTOMER Completed