Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T10OT01029
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/12/2010 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | May 12, 2010 FLOODPLAIN USE PERMIT # T10OT01029 PROJECT ADDRESS: 902 E 38th Street APPLICANT'S NAME: Tom Toole PROPERTY OWNER: Andy and Alex Vasquez This parcel lies within a City of Tucson identified Zone A, 100-year floodplain. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: PARCEL 129-14-1290, 902 E 38th Street. Tucson, AZ 85713, GRAND VIEW LOT 7 BLK 42. In a portion of Township 14 South, Range 14 East, Section 30, for a 10X 12 Storage Shed. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) The proposed shed is located within a City of Tucson identified Zone A, 100-year sheet flooding area. 4) Shed is to be constructed per plan signed and dated by Tom Toole (Dated 5/12/10). 5) Shed is to be securely anchored to prevent flotation, collapsing or lateral movement. Installation is to be per detail provided by Tom Toole, signed and dated 5/12/10. 6) Shed is to be used solely for storage. 7) No electrical components are proposed within the shed. Not electrical components will be servicing the shed. 8) No machinery and equipment which service the she such as furnaces, air conditioners, heat pumps, hot water heaters, washers, dryers, elevator lift equipment, electrical junction and circuit breaker boxes, and food freezers are permitted. 9) Shed to be built per flood vent detail provided by Tom Toole dated 5/12/10, have a minimum of two openings installed with a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. a. The bottom of all openings shall be no higher than one foot above grade. b. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. 6. Within 10 days after construction has been completed, the applicant must contact the District to verify all the requirements have been met. Please call (928) 771-3197 for final inspection. 10) All work shall conform to the approved details and general Site Plan, which are made part of this permit. 11) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T10OT01029. FOR INFORMATION PLEASE CALL 791-5550." 12) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 13) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 14) Contractor will need to call for floodplain use permit inspections by Development Services Department Engineering Division Inspection Team (791-5550) prior to and after the construction of the SFR. 15) See the associated activity T10CM01303. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of approval. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. (EXPIRATION DATE) Month: 5 Day: 12 Year: 2010 APPLICANT: Tom Toole ADDRESS: 4535 W Ina Road, Tucson, Arizona 85741 PHONE: (520) 579-0124 OWNER: Andy and Alex Vasquez ADDRESS: 902 E 38th St, Tucson, Arizona 85713 PHONE: SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |