Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10OT00324
Parcel: 11307198B

Review Status: Active

Review Details: RESUBMITTAL

Permit Number - T10OT00324
Review Name: RESUBMITTAL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
02/17/2010 BIANCA RAMIREZ ENGINEERING REVIEW Approved February 17, 2010
FLOODPLAIN USE PERMIT # T10OT00324
PROJECT ADDRESS: 1447 E Blacklidge Drive
APPLICANT'S NAME: Phillip Vezeziano
PROPERTY OWNER: Reza Sepassi


This parcel is impacted by a regulated 100-year breakout area. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:

Parcel 113-07-198B; 1447 E Blacklidge Drive, Tucson, AZ 85719, HEDRICK ACREAGE TRACT NO 3 LOT 14 EXC E66.72' S99.69' BLK F. In a portion of Township 13 South, Range 14 East, Section 31, for the construction of (3) single family residences.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) The proposed three single family residences are located within a City of Tucson regulated 100-year floodplain (breakout area), as defined in The Floodplain and Erosion Hazard Management Ordinance, Chapter 26 of the Tucson Code (Ordinance).

4) For purposes of this permit the following flood elevations shall be used for all three single family residences as determined by Drainage Report by JE Fuller and Associates.

Base Flood Elevation (BFE) = 2376.60 feet NGVD 1929
Regulatory Flood Elevation (RFE) = 2377.60 feet NGVD 1929

Finished floor of all the single family residences and the lowest point of any attached appliances including water heaters, air conditioning units, etc. are to be at or above the Regulatory Flood Elevation (RFE).

5) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to final approval of single family residences or electrical inspections. Each Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the single family residences as well as the identity and location of all other equipment/machinery servicing the single family residences. All elevation certificates are to be returned to Development Services - Engineering Department at 201 N Stone on the 1st floor - for review, approval and the release for inspections.

6) The existing/proposed weir invert is 2375.00 feet NGVD 1929 needs to be verified on "As Builts".

7) "As-Builts" will be required to be submitted prior to final approvals and shall include finish floor elevations for each of the structures as well as the inverts and soffits for all drainage structures (including water harvesting areas and wall openings). Ensure that "As-Builts' provide dimension of weir opening height and length.

8) Certification is required by an Arizona State Registered Professional Civil Engineer that the finished floor of the single family residences meet all the requirements of Section 26-9 of the Ordinance.

9) All work shall conform to the approved details and general Site Plan, which are made part of this permit.

10) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T10OT00324 FOR INFORMATION PLEASE CALL 791-5550."

11) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.

12) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

13) Contractor will need to call for floodplain use permit inspections by Development Services Department Engineering Division Inspection Team (791-5550) prior to and after the installation of the prefabricated storage container.

14) See the associated activities T09CM02827 and T09BU01577.


This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of approval. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 2 Day: 17 Year: 2011

APPLICANT: Phillip Veneziano
ADDRESS: 6011 E Grant Road, Tucson, Arizona 85712
PHONE: (520) 400-3000
OWNER: Reza Sepassi and Nahid Malekniazi
ADDRESS: 5216 N Standing Rock Pl, Tucson, AZ 85750-7029
PHONE:


SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.