Permit Number: T10OT00242
Parcel: 11805067B

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T10OT00242
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/02/2010 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: February 3, 2010
SUBJECT: SFR
TO: Rosa Montellano
LOCATION: 1867 W Puesblo Vista, T14S, R13E, Section 22, Ward 1
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T10CM00222 (First Review)

RESUBMITTAL REQUIRED: Site Plan and Floodplain Use Permit

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan or floodplain use permit at this time. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please verify that all elevations indicated on plan are on the NGVD 29 datum and labeled accurately.
2. Per City of Tucson Drainage Manual section 13.5.2.5 Elevation, any fill added to site for elevating structure is required to be protected from erosion, or extend at least 25' from the building in all directions.
3. Show the limits of the 100-year floodplain on the site plan; differentiate between FEMA floodplain and any determined floodplain limits. In addition, provide water surface elevations per D.S. 2-02.2.1.A.15.
4. Please list estimated cut & fill quantities on the site plan per D.S. 2-02.2.1.A.17.
5. Show dimensioned right-of-way on site plan per D.S. 2-02.2.1.A.19.
6. Verify that all easement of record have been graphically shown on the plan together with recording docket and page reference per D.S. 2-02.2.1.20.
7. Please provide existing topographic contours at intervals not exceeding two (2) feet as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.A.23. Provide contour interval on plan.
8. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27.
9. Please provide existing and proposed zoning of parcel and adjacent parcels, including those across streets and alleys D.S. 2-02.2.1.A.28.
10. Show site plan number and floodplain use permit number in the lower right hand corner of each sheet per D.S. 2-02.2.1.A.29.
11. List the consulting engineer and drafter on the plans with the pertinent information, including name address, phone number, etc.
12. Provide legend on site plan and provide all symbols in legend.
13. Revise sight visibility triangles to be depicted on site plan accurately. Stem of triangle should begin at intersection of edge of curbs.
14. Recommend realigning home to be located outside the floodplain limits.
15. Additional comments may be forthcoming.

Floodplain Use Permit:
1. Provide drainage report signed and sealed by a professional engineer will be required.
2. Revise Q100 to reflect actual flow for the location of the parcel.
3. Verify that depth of flow across driveway is 1' or less and meets all weather access criteria.
4. Additional comments may be forthcoming.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax

Final Status

Task End Date Reviewer's Name Type of Review Description
03/09/2010 CINDY AGUILAR OUT TO CUSTOMER Completed
03/09/2010 SUE REEVES REJECT SHELF Completed