Permit Number: T10MH00001
Parcel: 11810134D

Review Status: Completed

Review Details: MOBILE HOME

Permit Number - T10MH00001
Review Name: MOBILE HOME
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2010 TERRY STEVENS ZONING REVIEW Approved
01/04/2010 TERRY STEVENS NPPO REVIEW Passed
01/04/2010 GERRY KOZIOL WWM REVIEW Approved
01/04/2010 LOREN MAKUS ENGINEERING REVIEW Approved January 4, 2010
FLOODPLAIN USE PERMIT # T09OT02544
PROJECT ADDRESS: 2424 S Cottonwood Lane #140
APPLICANT'S NAME: Precision Mobile Home Installation
PROPERTY OWNER: Verde Plaza Mobile Home Park


This parcel lies in a FEMA AE Zone map number 040076 C 2228K,
effective date February 8, 1999. Federal law requires that
a flood insurance policy be obtained as a condition of a
federally backed mortgage or loan that is secured by a building
located within a SFHA. The applicant is authorized to use
a portion of the flood hazard area in the City of Tucson,
Arizona, on the property described as:

2424 S Cottonwood Lane #142, Tucson, AZ 85713, COTTONWOOD
PARK LOT 114 EXC THAT PTN LYG N LINE 11421.11 S SILVERLAKE
RD EXC THAT PTN LYG SW CENTERLINE OF DRGWY. In a portion
of Township 14 South, Range 13 East, Section 23, for the
set-up of a replacement manufactured home.

The applicant agrees to comply with City of Tucson Floodplain
and Erosion Hazard regulations, and is particularly bound
by the conditions stated below. Violation of any of the
conditions stated or referred to below, as determined by
the City Engineer, shall be grounds for revocation of this
permit. Responsibility for renewal of this permit, if necessary,
is with the applicant. Issuance of this permit does not constitute
a waiver of other requirements contained in the Tucson City
Code, Land Use Code, or any other Federal, State, County,
or local regulation. No use other than as permitted herein
is allowed. Additional uses allowed under City of Tucson
Floodplain and Erosion Hazard Regulations and Watercourse
Amenities, Safety, and Habitat regulations require the issuance
of an additional Floodplain Use Permit.

The following conditions apply to this permit:

1) This permit becomes invalid and is subject to additional
floodplain review, if any required development permit changes
the configuration of the improvement, or, if there is any
further disturbance within the floodplain other than that
outlined in this application. This floodplain use permit
may be subject to conditions or restrictions designed to
reduce or mitigate the potential damage or hazard to life
or property resulting from development within the regulatory
floodplain, floodway or erosion hazard areas as determined
by the project engineer and accepted by the City of Tucson.

2) Except as approved by the City Engineer prior to the start
of construction, development under this permit shall not
obstruct, retard or divert the existing flow of floodwaters
from or to adjacent properties.

3) The proposed manufactured home set-up is located within
an existing manufactured home park, as defined in The Floodplain
and Erosion Hazard Management Ordinance, Chapter 26 of the
Tucson Code (Ordinance), and is exempt from the requirement
of placing the manufactured home replacement on a permanent
foundation.

4) For purposes of this permit the following flood elevations
shall be used:
Base Flood Elevation (BFE) = 2381.75 feet NGVD
1929
Regulatory Flood Elevation (RFE) = 2382.75 feet NGVD 1929
The bottom of the structural frame of the manufactured home
and lowest point of any attached appliances to be at or above
the Regulatory Flood Elevation (RFE).

5) Floodplain Approval of elevation certificate, prepared
by an Arizona State Registered Land Surveyor, is required
prior to manufactured home electrical inspection or habitation.
The Elevation Certificate must include the identity and elevation
of the lowest service equipment/machinery servicing the manufactured
home as well as the identity and location of all other equipment/machinery
servicing the manufactured home.

6) Certification by an Arizona State Registered Professional
Civil Engineer that the installation of the manufactured
home meets all the requirements of Section 26-9 of the Ordinance
is required.

7) The manufactured home must be securely anchored and installed
with tie downs per State of Arizona requirements.

8) All work shall conform to the approved details and general
site plan (T09MH00122), which are made part of this permit.


9) This Floodplain Use Permit and plans shall be kept in a
readily accessible location on site at all times.

10) Any additional future disturbance of the floodplain shall
have separate floodplain use permit applications submitted
to this office for review and approval.

This Floodplain Use Permit will be automatically revoked and
becomes invalid for non-compliance to conditions set forth
in this permit.