Permit Number: T10EL01797
Parcel: 99999999B

Address:
10603 E I10

Review Status: Completed

Review Details: BILLBOARD-BLDG/ELEC10days

Permit Number - T10EL01797
Review Name: BILLBOARD-BLDG/ELEC10days
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/27/2010 LEERAY HANLY BUILDING-COMMERCIAL REVIEW Approved
07/27/2010 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Approved
08/09/2010 GLENN MOYER ADMINISTRATIVE ADMIN REVIEW Denied Comments below are for the lighting relocation & electrical repair submittal
for COT ID# 597 at 10401 East I-10 (East) (T10EL01797). If junction box is
to be used between the two new ballasts, that must be shown on the plan.

Sheet 1 of 3

No comments.

Sheet 2 of 3

1. Title Block: add Stipulation address (10401 E. I-10 (W)) (no objection
to PDSD staff making correction with permission of the EOR).

2. Panel Schedule: provide correct amperage rating and dimensions for the
Sangamo panel (or mark unknown) (no objection to PDSD staff making
correction with permission of the EOR).

3. Comment for future reference: Notes: add notation that any excess
fixtures, conduit, connectors, wiring, or breakers no longer being used to
be removed.

4. Comment for future reference: Notes: add notation that no junction boxes
or other fixtures where wire connections are made to be installed or remain
on the load side of the panel other than those depicted on the plan.

5. Comment for future reference: Panel Schedule: clarify if the clock box
has a dedicated circuit or is wired into the fluorescent fixture circuit
(and adjust volt-amps as necessary).

6. Comment for future reference: One-Line Diagram: depict and include
circuitry for ballasts, clock box and any other fixtures where wire
connections are made.

Sheet 3 of 3

1. Title Block: add Stipulation address (10401 E. I-10 (W)) (no objection
to PDSD staff making correction with permission of the EOR).

Final Status

Task End Date Reviewer's Name Type of Review Description
09/01/2010 CPIERCE1 OUT TO CUSTOMER Completed
09/01/2010 SUE REEVES REJECT SHELF Completed