Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL01583
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/09/2010 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Approved | |
07/09/2010 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
07/29/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | BRC Comments Comments below are for the lighting modification & electrical repair submittal for COT ID# 183 at 720 South Stone Avenue (T10EL01583). Sheet 1 of 4 No comments. Sheet 2 of 4 1. Provide the calcs related to the light arm support attachment as part of plan set (May 20, 2010; June 9, 2010 revisions). Sheet 3 of 4 1. Notes (Bullet #4), Existing Electrical Riser Diagram, Elevation & Partial Plan View: reduce the number of #12 replacement conductors between the panel and first junction box from three (3) to two (2); number of existing conductors to be field confirmed. 2. Notes (Bullet #7): resolve inconsistency of use of SOOW flex cable shown on Partial Plan View and Manufacturer's Spec Sheet with rigid connection (3/4" nipple) between support arm and junction box; clarify any need to use SOOW flex cable if entirely housed within conduit; if exposed SOOW flex cable is to be used, add notation specifying minimum and maximum distances below junction boxes that flex cable drip loops/slack is to extend (or otherwise provide appropriate limit on length of flex cables). 3. Notes: add notation that no junction boxes or other fixtures where wire connections are made to be installed or remain on the load side of the panel other than those depicted on the plan. 4. Notes: add notation that any excess fixtures, conduit, connectors, wiring, or breakers no longer being used to be removed. 5. Elevation: indicate location of SOOW flex cable (if used). 6. Elevation: depict existing ballasts with notation to be removed. 7. Panel Schedule & Partial Plan View: change number of circuits from two per face to one per face. 8. Panel Schedule: correct panel amperage. 9. Shield Diagram: depict in top-down configuration with notation: "Zero Uplight Above 90 Degrees From Nadir Ref IES File #104313" (see EDC submittals). 10. Add notation: "Special inspection required prior to final inspection for installation of light fixture support arms, light fixtures, shields, gaskets, and associated parts. Inspector to verify that light fixtures are installed with shield in a horizontal position so that no light is emitted above the horizontal plane and that mean lumen output of the light fixtures does not exceed 1000 lumens per horizontal foot of billboard face, as per the City of Tucson/Pima County Outdoor Lighting Code and the City of Tucson-Clear Channel Outdoor Stipulation (Pima County Superior Court No. C20003712)". Sheet 4 of 4 No comments. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
09/27/2010 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
09/27/2010 | SUE REEVES | REJECT SHELF | Completed |