Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL01286
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/02/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. GENERAL: REFERENCE EXHIBIT 9 FOR REPLACEMENT OF ITEMS INDICATED ON SHEET 2. VERIFY NEW C6X10.5 MOUNTING BRACKETS, NEW 2.875" DIAMETER PIPES, NEW 2.375" DIAMETER PIPE LIGHT ARMS, NEW STIFFENER PLATES, AND NEW LIGHT FIXTURES ARE ALLOWED AS AUTHORIZED REPAIRS AND ALTERATIONS. 2. GENERAL: REPAIRS INDICATED FOR THIS BILLBOARD WILL BE DISCUSSED AT A FUTURE MEETING. APPROVAL OF THIS PROJECT WILL BE WITHHELD UNTIL THAT MEETING. 3. SHEET 1; BILLBOARD NOTES 7: REFERENCE IS MADE TO SHEET 2 OF 3. THERE ARE 4 TOTAL SHEETS. REVISE NOTE. 4. SHEET 1; BILLBOARD NOTES 9: REVIEW ALL PARAGRAPH REFERENCES LISTED AND VERIFY THOSE RELATE TO THE WORK DESCRIBED ON SHEET 2. REVISE REFERENCES AS REQUIRED. 5. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 06/07/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | Please find below comments on the lighting modification & electrical repair submittal for COT ID# 391 at 1346 North Stone Avenue (T10EL01286). Mark Mayer Billboard Review Committee 3361 East 23rd Street Tucson, Arizona 85713 520.326.4522 Sheet 1 of 3 1. Billboard Notes (#2): indicate location on APN# 115-08-007E as well as APN# 115-08-007C. 2. Billboard Notes (#7): correct sheet reference in parentheses (from Sheet 2 of 3 to Sheet 3 of 4). Sheet 2 of 3 1. Provide calcs for the light arm support attachment and justification for adding stiffeners. 2. Add notation clarifying that stiffener plates are only to be added to the two uprights supporting the light arms and not to the other four uprights. Sheet 3 of 3 1. Notes (first set under Mean Lumen Calculation): add fourth note indicating that only lamp to be used is that specified for the photometric test detailed on Sheet 4 (Philips MS320/U/PS (Bulb size: ED-28)) 2. Add panel schedule indicating circuits, breakers, and respective loads (as in submittals where replacement of service is indicated); if there is any change in circuits or breakers compared to existing panel, add notation describing such change). 3. Provide circuit plan using Partial Plan View or otherwise, showing ballasts and any junction boxes or other fixtures where wire connections are made on the load side of the panel box and indicating the circuit number as shown in the panel schedule. 4. Notes (Bullet #3): clarify that the two junction boxes to be installed are the total number being installed or remaining on the load side of the panel box. 5. Notes (Bullet #4), Elevation & Partial Riser Diagram: reduce the number of #12 replacement conductors between the panel and junction box from four to three (two 320-watt lamps do not justify a second circuit). 6. Notes (Bullets #4 & #5): indicate the number and type of each #12 conductor in parentheses (e.g., (1) hot, (1) neutral & (1) ground). 7. Notes: add notation that no junction boxes or other fixtures where wire connections are made to be installed or remain other than those depicted on the plan. 8. Notes: add notation that any excess fixtures, conduit, connectors, wiring, or breakers no longer being used, including those associated with the second circuit for the third and fourth light fixtures, to be removed. 9. Notes: add notation specifying maximum distance below junction boxes that flex cable drip loops/slack is to extend (or otherwise provide appropriate limit on length of flex cables). 10. Elevation: depict loops of flex cable between the two junction boxes and light fixtures. 11. Elevation: depict existing ballasts with notation to be removed. 12. Partial Vicinity Map: correct Brachman St. to Drachman St. Sheet 4 of 4 1. Include manufacturer's spec sheet for Philips MS320/U/PS lamp specified in photometric test. |
| 06/14/2010 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | Project: T10EL01286 1346 N Stone Electrical denied, 1. The plans do not show the conversion fron the junction box to the support pipe which the SOOW Cable or the UF Cable go through, then the conversion from the support pipe to a different raceway then into the fixture. 2.Does the fixture provide a threaded hub ? 3. From what documentation is the lumen count for the 320 W MH fixture obtained ? Ray T Majuta City of Tucson,PDSD Elect Pln CK 6/2/10 Ray.majuta@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/25/2010 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |