Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL01284
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/02/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. GENERAL: REFERENCE EXHIBIT 9 FOR REPLACEMENT OF ITEMS INDICATED ON SHEET 2. VERIFY NEW C6X10.5 MOUNTING BRACKETS, NEW 2.875" DIAMETER PIPES, NEW 2.375" DIAMETER PIPE LIGHT ARMS, NEW STIFFENER PLATES, AND NEW LIGHT FIXTURES ARE ALLOWED AS AUTHORIZED REPAIRS AND ALTERATIONS. 2. GENERAL: REPAIRS INDICATED FOR THIS BILLBOARD WILL BE DISCUSSED AT A FUTURE MEETING. APPROVAL OF THIS PROJECT WILL BE WITHHELD UNTIL THAT MEETING. 3. SHEET 1; BILLBOARD NOTES 7: REFERENCE IS MADE TO SHEET 2 OF 3. THERE ARE 4 TOTAL SHEETS. REVISE NOTE. 4. SHEET 1; BILLBOARD NOTES 9: REVIEW ALL PARAGRAPH REFERENCES LISTED AND VERIFY THOSE RELATE TO THE WORK DESCRIBED ON SHEET 2. REVISE REFERENCES AS REQUIRED. 5. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 06/02/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | Project: T10EL01284 430 N Stone Av Electrical Plans denied, see comments from T10EL01287. Ray T Majuta City of Tucson PDSD Elect Pln Ck 6/2/10 Ray.Majuta@tucsonaz.gov |
| 06/23/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | BRC Review Comments Comments below are for the lighting modification & electrical repair submittal for COT ID# 27 at 430 North Stone Avenue (T10EL01284). Sheet 1 of 3 1. Billboard Notes (#7): correct sheet reference in parentheses (from Sheet 2 of 3 to Sheet 3 of 4). Sheet 2 of 3 1. Provide calcs for the light arm support attachment and justification for adding stiffeners. 2. Add notation clarifying that stiffener plates are only to be added to the two uprights supporting the light arms and not to the other four uprights. Sheet 3 of 3 1. Notes (first set under Mean Lumen Calculation): add fourth note indicating that only lamp to be used is that specified for the photometric test detailed on Sheet 4 (Philips MS320/U/PS (Bulb size: ED-28)). 2. Add panel schedule indicating circuits, breakers, and respective loads (as in submittals where replacement of service is indicated); if there is any change in circuits or breakers compared to existing panel, add notation describing such change). 3. Provide circuit plan using Partial Plan View, one-line engineering plan, or otherwise, showing all junction boxes or other fixtures where wire connections are made on the load side of the panel box and indicating the circuit number as shown in the panel schedule. 4. Notes (Bullet #3): reduce the number of junction boxes from three (3) to two (2) and indicate that this is the total number to be installed or or remaining on the load side of the panel box. 5. Notes (Bullets #4 & #5): indicate the number for of each type of #12 conductor in parentheses (e.g., (1) hot, (1) neutral & (1) ground). 6. Notes (Bullet #5), Elevation & Partial Riser Diagram: reduce the number of #12 replacement conductors between the panel and first junction box from four (4) to three (3). 7. Notes: add notation that no junction boxes or other fixtures where wire connections are made to be installed or remain other than those depicted on the plan. 8. Notes: add notation that any excess fixtures, conduit, connectors, wiring, or breakers no longer being used, including those associated with the second circuit for the third and fourth light fixtures on each face, to be removed. 9. Notes: add notation specifying maximum distance below junction boxes that flex cable drip loops/slack is to extend (or otherwise provide appropriate limit on length of flex cables). 10. Elevation: delete leftmost junction box. 11. Elevation: depict existing ballasts with notation to be removed. 12. Elevation: indicate location of flex cable loops between the two junction boxes and light fixtures. 13. Add notation that a special inspection is to be performed for compliance as provided for in Section 306 of the 1997 Uniform Administrative Code (or any applicable successors or amendments thereto; as per Subparagraph 8.3.4 of the Stipulation). Sheet 4 of 4 1. Include manufacturer's spec sheet for Philips MS320/U/PS lamp specified in photometric test. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/04/2010 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |