Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL01277
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/01/2010 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 09/01/2010 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 09/09/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | BRC Commnets Below are comments on the lighting modification & electrical repair resubmittal (8/10/10) for COT ID# 427 at 4206 East Grant Road (T10EL01277). Sheet 1 of 3 No comments. Sheet 2 of 3 No comments. Sheet 3 of 3 1. Notes (Bullet #3), Elevation & Partial Riser Diagram: reduce the number of #12 replacement conductors between the panel and first junction box from six (6) to three (3). [Comment #4, 6/7/10] 2. Notes (Bullet #4), Elevation & Partial Plan View: reduce the number of #12 replacement conductors between the first junction box and the second pair of junction boxes from three (3) to two (2). [Comment #5, 6/7/10] 3. Panel Schedule: reduce the number of lighting circuits from four (4) to (2) [See Comment #2, 6/7/10] 4. Elevation: indicate the locations where the SOOW cable is to be used with a note clarifying that those are the only locations where the SOOW is to be installed (apparently between the last junction boxes and the light fixtures through the ½" EMT and connected light arms supports). [See Comment #12(B), 6/7/10] 5. Elevation: delete the reference to and wavy line to the ½" EMT from the panel upwards as no such ½" EMT conduit exists (the only conduit exiting the panel box is ¾" armored cable connected to ¾" EMT approximately two (2) feet above the panel top). 6. Manufacturer's 360 Shield Cut-Sheet: add adjacent notation clarifying that shield is to be installed on top-mounted light fixtures directing light downward below the horizontal plane as per the installation utilized for the photometric test on Sheet 4 (or otherwise clarify that the bottom-mounted configuration shown in the manufacturer's cut-sheet does not represent the installation for this application). 7. Add standard notation: "Special inspection required prior to final inspection for installation of light fixture support arms, light fixtures, shields, gaskets, and associated parts. Inspector to verify that light fixtures are installed with shield in a horizontal position so that no light is emitted above the horizontal plane and that mean lumen output of the light fixtures does not exceed 1000 lumens per horizontal foot of billboard face, as per the City of Tucson/Pima County Outdoor Lighting Code and the City of Tucson-Clear Channel Outdoor Stipulation (Pima County Superior Court No. C20003712)". [Note: this notation may be integrated with the more specific notation on the special inspection required for the light fixture gaskets already on the plan]. Sheet 4 of 4 No comments. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/27/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |