Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL00833
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/12/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 04/19/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | Project: T10EL00833 (Billboard) Denied, how is transition made on Sheet 2 of 3, where 1/2" EMT conduit goes to 3/4" Rigid conduit to fixture. Ray T Majuta, PDSD City of Tucson Elect Plan Review, 4/20/10 520-837/4988 |
| 05/03/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | Please find below comments on the lighting modification & electrical repair submittal for COT ID# 146 at 7042 East Broadway Boulevard (T10EL00833). Mark Mayer Billboard Review Committee 3361 East 23rd Street Tucson, Arizona 85713 520.326.4522 Sheet 1 of 3 1. Comment for future reference only: Billboard Notes (#4): opening line should be amended to read "Latitude and Longitude of billboard at approximate center of footprint:" (also deleting line at bottom). 2. Comment for future reference only: Billboard Notes (#5): change "Faces" to "faces". 3. Comment for future reference only: Billboard Notes (#11): delete comma after "relocated". 4. Comment for future reference only: Title Block: change title to "Lighting Modification and Electrical Repair Site Plan". 5. Comment for future reference only: delete "COT Activity No. __________" under the title block (as per 4/27/10 meeting; retain for resubmittals only at revised location). Sheet 2 of 3 1. Title Block: enter T10EL00833 into COT Activity No. blank. 2. Title Block: change title to "Lighting Modification and Electrical Repair Plan" and delete quotation marks. 3. Note (Bullet #2): indicate ¾" rigid conduit as "new". 4. Note (Bullet #3): indicate HO lamp with matching specifications 5. Note (Bullet #5): indicate ballast to match HO (800 ma). Sheet 3 of 3 1. Title Block: enter T10EL00830 into COT Activity No. blank. 2. Title Block: change title to "Lighting Modification and Electrical Repair Plan" and delete quotation marks. 3. Mounting Detail: show detail of mounting bracket in three views with dimensions (assure that vertical position of unistrut matches in all views and that the three views are reasonably scaled to each other). 4. Description of Existing Lamp: change "Existing" to "New" and indicate HO lamp with matching specifications. 5. Description of Existing Ballast: change "Existing" to "New" and indicate ballast to match HO (800 ma). 6. Side View: add dimension between top stringer and top of upright/face panel (alternatively, depict all four stringers). |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/17/2010 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 08/17/2010 | SUE REEVES | REJECT SHELF | Completed |