Permit Review Detail
Review Status: Active
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL00832
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/13/2010 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 08/13/2010 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 09/08/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | BRC Comments Below are comments on the lighting modification & electrical repair resubmittal (8/3/10) for COT ID# 38 at 724 North Main Avenue (T10EL00832). The electric service was disconnected and the meter removed prior to July 22, 2010. As such, the service no longer exists and there is no basis for replacement under the Stipulation. The comments below are provided in the event that such a basis is subsequently established. The comment regarding the replacement panel is new, but the upgrade from the current service configuration to a 206 panel is so substantial without any need to meet NEC minimums, that it should be addressed now for pending and future panel replacements on single-faced billboards. Sheet 2 of 3 1. Notes (Bullet #7), Manufacturer's Literature Sheet, Electrical Riser Diagram, Elevation & Panel Schedule (including entries for Amperes, Mains, Height, Width & Depth): change replacement panel (206PROG (206MRPS in the Elevation)) to a 122 panel; for a single faced billboard, there is no need for the upgrade from the current 122 panel to the 206 panel where the 122 is permissible under the 2005 NEC (230.79; two branch circuit maximum: one for timer controls and one for lighting). 2. Panel Schedule: correct the volt-amp entries for Circuit #1 and associated sums, based on the ballast manufacturer's stated input watts (248 watts per two lamp fixture (F96T12HO)), if the 125% continuous load factor is applied in the panel schedule, this figure would then be 312.5 v-a; if otherwise, provide the calculations as to how the v-a entries were arrived at; these entries need to be standardized for all pending and future panel schedules. Sheet 3 of 3 1. End View: delete one of two backrails, as per 5/9/10 Comment #4 (replacement of one angle iron light support with a wood backrail has only been accepted where there were no existing backrails at all). 2. New Ballast: include the manufacturer's spec for input watts for the application. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/08/2010 | GERARDO BONILLA | REJECT SHELF | RECEIVED |