Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL00832
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/12/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 04/19/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | Project: T10EL00832 Sheets 2 and 3 show a 1/2'' conduit bring up conductors to the light fixture, however it changes into a 3/4'' conduit for support of the fixture, how does it change ? Also the service is being upgraded, still 60 amp service, everthing electrical is being replaced, is this allowed by City PDSD and Clear Channel aggreement ? Ray Majuta, C of T PDSD, Elect Plan Review 4/20/10 Ray.Majuta@tucsonaz.gov |
| 05/10/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | Please find below comments on the lighting modification & electrical repair submittal for COT ID# 38 at 724 North Main Avenue (T10EL00832). Mark Mayer Billboard Review Committee 3361 East 23rd Street Tucson, Arizona 85713 520.326.4522 Sheet 1 of 3 1. Comment for future reference only: Billboard Notes (#5): change "Faces" to "faces". 2. Comment for future reference only: Billboard Notes (#11): delete comma after "relocated". 3. Comment for future reference only: Title Block: change title to "Lighting Modification and Electrical Repair Site Plan". 4. Comment for future reference only: Title Block: delete "COT Activity No. __________" under the title block (as per 4/27/10 meeting; retain for resubmittals only and move to better location, with assigned project number filled in). Sheet 2 of 3 1. Title Block: change title to "Lighting Modification and Electrical Repair Plan" (do not include quotation marks). 2. Title Block: enter T10EL00832 into the COT Activity No. blank. 3. Notes (Scope of Work): add bullet with description of panel replacement. 4. Electrical Riser Diagram: provide detail to establish a standard configuration relative to the I-beam where the entire service is being replaced on twin-beam poster panels (with or without backing panel; add top view if appropriate; delete junction boxes where using Phillips ballast(s)). [Note: refer to initial comment in this regard for the resubmittal for T10EL00530/2601 E. Grant Rd.] 4. Panel Block: delete entry for spare circuit. Sheet 3 of 3 1. Title Block: change title to "Lighting Modification and Electrical Repair Plan" (do not include quotation marks). 2. Title Block: enter T10EL00832 into the COT Activity No. blank. 3. Delete vertical extension of each light arm support from just below second stringer from the top to third stringer from the top and delete added clamp on each third stringer from the top; move horizontal run of ½" EMT conduit and associated elbows accordingly (all as per 4/27/10 meeting). 4. End View: delete one of the two wood backrails shown; if lower backrail is to remain, it may be replaced under this permit. 5. Description of Ballast: change "Ballast" to "New Ballast" |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/04/2010 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 08/04/2010 | SUE REEVES | REJECT SHELF | Completed |