Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC10days
Permit Number - T10EL00748
Review Name: BILLBOARD-BLDG/ELEC10days
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/07/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
04/12/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
04/15/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | COMMENTS ON LIGHTING RELOCATION & ELECTRICAL REPAIR SUBMITTAL FOR CLEAR CHANNEL BILLBOARD COT ID #465 AT 2436 NORTH 1ST AVENUE Lighting Relocation and Repair Site Plan (Sheet 1 of 1) 1. Comment for future reference: Billboard Notes (#4): opening line should be amended to read "Latitude and Longitude of billboard at approximate center of footprint:" (also deleting line at bottom). 2. Comment for future reference: Title Block: change title to "Lighting Relocation and Electrical Repair Site Plan". 3. Comment for future reference: add "COT Activity No. __________" near the title block. [Note to PDSD staff: where CCO has placed this line on subsequent applications there is insufficient space to insert the handwritten number; this entry may be better located at the upper right of the plan sheet where such activity numbers are more typically written with the Site Plan Requirements stating a minimum font size that approximates the handwritten entries]. Lighting Relocation and Repair Plan (Sheet 2 of 3) 1. Add "COT Activity No. T10EL00748" near the title block (or at alternative location as determined by PDSD staff). 2. Title Block: change title to "Lighting Relocation and Electrical Repair Plan" and delete quotation marks. 3. Notes (Bullet #2): indicate ¾" rigid conduit as "new". 4. Notes (Bullets #4 & #5), Elevation & Electrical Riser Diagram: change conduit size from ¾" EMT to ½" EMT; alternatively, retain the current configuration as to ballast location and conduit runs except for additional conduit runs to reach the top-mounted light fixtures. 5. Notes (Bullet #7): indicate the conduit size and type between the ballasts and light fixtures (size should be 1/2" except for any double bundles of #18 wire). 6. Elevation: depict ballasts in existing locations. Lighting Relocation and Repair Plan (Sheet 3 of 3) 1. Add "COT Activity No. T10EL00748" near the title block [or at alternative location as determined by PDSD staff]. 2. Title Block: change title to "Lighting Relocation and Electrical Repair Plan Detail" and delete quotation marks. 3. Mounting Detail: show detail of mounting bracket in three views with dimensions. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/07/2010 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |