Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC10days
Permit Number - T10EL00532
Review Name: BILLBOARD-BLDG/ELEC10days
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/11/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
03/11/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
03/24/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | COMMENTS ON LIGHTING RELOCATION SUBMITTAL FOR CLEAR CHANNEL BILLBOARD COT ID #492 AT 3712 NORTH ORACLE ROAD Lighting Removal, Replacement and/or Relocation Site Plan (Sheet 1 of 3) 1. Billboard Notes (#7; 3rd Bullet): indicate lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 2. Billboard Notes (#8 & #9): amend "modification" to "modification and repair". 3. Billboard Notes (#13): after "premises", strike the balance of the sentence and insert "except upon request in instances where the fixtures cannot be secured on site, in which case the fixtures may be removed from the premises only if marked for identification by a third party special inspector approved by the City of Tucson". 4. Title Block: amend title to "Lighting Relocation Site Plan". Electrical Plan Sheet (Sheet 2 of 3) 1. Billboard Notes (#4): add "Approximate Center of Footprint". 3. Billboard Notes (#7; 2nd Paragraph): indicate lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 4. Electrical Riser Diagram: indicate the size, type, and number of conductors between the ballasts and the lamp sockets. 6. Electrical Riser Diagram: clarify the nature of the two boxes depicted below the ballasts. 7. Title Block: add title "Lighting Relocation Site Plan". Overhead Fluorescent Lighting (Sheet 3 of 3) 1. Top View: specify the distance of the rigid conduit run between the two 42" extensions outward from the face panels iron metal halide lighting supports on back side of uprights to be removed. 2. Mounting Detail: clarify the substitution of pole spikes for the screws indicated in the engineer's letter (Exhibit 8 of the Stipulation). 3. Description of New Ballast: conform to existing ballast (Universal) shown on Sheets 1 and 2. 4. Add the street address and COT ID# to the plan sheet. 5. In lower right corner, change "Page 3 of 3" to "Sheet 3 of 3". 6. Add engineer's stamp to the plan sheet [Note: it would be preferable for the engineer to incorporate the details from this sheet into the electrical plan sheet]. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/24/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
03/24/2010 | SUE REEVES | REJECT SHELF | Completed |