Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL00531
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/05/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
05/11/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
06/01/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Approved | Please find below comments on the lighting modification & electrical repair resubmittal for COT ID #508 at 1829 North Oracle Road (T10EL00531). Note that for Sheet 2, only Comments #1 & #6 related to the junction box, as newly depicted in the resubmittal (and discussed at the 5/25/10 meeting), are holding up BRC approval at this time Mark Mayer Billboard Review Committee 3361 East 23rd Street Tucson, Arizona 85713 520.326.4522 Sheet 1 of 3 1. Comment for future reference only: Billboard Notes (#13): delete this note as not being applicable to replacement of metal halide fixtures with a fluorescent fixtures. 2. Comment for future reference only: Title Block: change title to "Lighting Modification and Electrical Repair Plan" (do not include quotation marks). 3. Comment for future reference only: relocate "COT Activity No.T10EL00531" from lower margin to standard location in title block (as per 4/27/10 meeting). Sheet 2 of 3 1. Billboard Notes (#7; 4th Bullet): indicate elbow instead of junction box (alternatively, indicate appropriately rated disconnect if NEC requires a disconnect at this location). 2. Billboard Notes (#13): delete this note as it is not being applicable to replacement of metal halide fixtures with a fluorescent fixtures. 3. Notes: add notation that number of #12 replacement conductors indicated includes ground wire. 4. Billboard Notes: add notation that no junction boxes to be used other than for wire connection purposes and that no junction boxes to be installed or remain other than those depicted on the plan. 5. Notes: add notation that number of #12 replacement conductors indicated includes ground wire. 6. Partial Riser Diagram (Existing I-Beam of Structure) & Partial Plan View: delete junction box and insert elbow (alternatively, insert appropriately rated disconnect if NEC requires a disconnect at this location) 7. Title Block: amend title to "Lighting Modification & Electrical Repair Site Plan". Sheet 3 of 3 1. Comment for future reference only: Title Block: change title to "Lighting Modification and Electrical Repair Plan" (do not include quotation marks). |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/10/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
06/10/2010 | SUE REEVES | REJECT SHELF | Completed |