Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL00531
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/11/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
03/11/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
03/17/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | COMMENTS ON LIGHTING MODIFICATION & REPAIR SUBMITTAL FOR CLEAR CHANNEL BILLBOARD COT ID #508 AT 1829 NORTH ORACLE ROAD Lighting Removal, Replacement and/or Relocation Site Plan (Sheet 1 of 3) 1. Billboard Notes (#7; 1st Bullet): add removal of horizontal light arm supports. 2. Billboard Notes (#7; 3rd Bullet): indicate lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 3. Billboard Notes (#8): amend "modification" to "modification and repair". 4. Title Block: amend title to "Lighting Modification & Repair Site Plan". Electrical Plan Sheet (Sheet 2 of 3) 1. Billboard Notes (#4): add "Approximate Center of Footprint". 2. Billboard Notes (#7; 2nd Paragraph): indicate the lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 3. Partial Riser Diagram: indicate the size, type, and number of conductors between the ballast and the lamp sockets. 4. Partial Riser Diagram & Elevations: indicate the size, type, and number of conductors between the meter and the weatherhead. 5. Partial Riser Diagram & Elevations: clarify why ¾" EMT conduit is being shown where ½" EMT conduit should be adequate for a single ballast/single fixture application; if changed to ½" EMT on plans, conform same in Billboard Notes on Sheets 1 & 2 (#7; 4th Bullet/3rd Paragraph) and Back View on Sheet 3. 6. Title Block: amend title to "Lighting Modification & Repair Site Plan". Overhead Fluorescent Lighting (Sheet 3 of 3) 1. Description of New Ballast: conform ballast information to that in Scope of Work in Sheets 1 & 2. 2. End View: delete the upper backrail on back side of uprights. 3. Mounting Detail: clarify the substitution of pole spikes for the screws indicated in the engineer's letter (Exhibit 8 of the Stipulation). 4. End View: add dimension for distance that fixture extends horizontally from point of attachment. 5. Back View: add length dimension for the light fixture. 6. Add the street address and COT ID# to the plan sheet. 7. Add engineer's stamp to the plan sheet [Note: it would be preferable for the engineer to incorporate the details from this sheet into the electrical plan sheet]. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
04/30/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
04/30/2010 | SUE REEVES | REJECT SHELF | Completed |