Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL00530
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/11/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 03/11/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 04/09/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | COMMENTS ON LIGHTING MODIFICATION & REPAIR SUBMITTAL FOR CLEAR CHANNEL BILLBOARD COT ID #439 AT 2601 EAST GRANT ROAD Lighting Removal, Replacement and/or Relocation Site Plan (Sheet 1 of 3) 1. Billboard Notes (#7; 3rd Bullet): indicate lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 2. Billboard Notes (#8 & #9): amend "modification" to "modification and repair". 3. Title Block: amend title to "Lighting Modification & Repair Site Plan". Electrical Plan Sheet (Sheet 2 of 3) 1. Billboard Notes (#4): add "Approximate Center of Footprint". 3. Billboard Notes (#7; 2nd Paragraph): indicate lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 4. Electrical Riser Diagram: indicate the size, type, and number of conductors between the ballasts and the lamp sockets. 6. Electrical Riser Diagram: clarify the nature of the two boxes depicted below the ballasts. 7. Electrical Riser Diagram: indicate the manufacturer and model number for the replacement meter socket box. 8. Title Block: add title "Lighting Modification & Repair Site Plan". Overhead Fluorescent Lighting (Sheet 3 of 3) 1. Top View: specify the distance of the rigid conduit run between the two 42" extensions outward from the face panels iron metal halide lighting supports on back side of uprights to be removed. 2. Mounting Detail: clarify the substitution of pole spikes for the screws indicated in the engineer's letter (Exhibit 8 of the Stipulation). 3. Add the street address and COT ID# to the plan sheet. 4. In lower right corner, change "Page 3 of 3" to "Sheet 3 of 3". 5. Add engineer's stamp to the plan sheet [Note: it would be preferable for the engineer to incorporate the details from this sheet into the electrical plan sheet]. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/22/2010 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 04/22/2010 | SUE REEVES | REJECT SHELF | Completed |