Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC30days
Permit Number - T10EL00528
Review Name: BILLBOARD-BLDG/ELEC30days
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/11/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
03/11/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
03/17/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | COMMENTS ON LIGHTING MODIFICATION & REPAIR SUBMITTAL FOR CLEAR CHANNEL BILLBOARD COT ID #46 AT 27 WEST SPEEDWAY BOULEVARD Lighting Removal, Replacement and/or Relocation Site Plan (Sheet 1 of 3) 1. Correct east-west dimensions on aerial photograph overlay: the sum of the dimensions need to add; the 10-foot width of the billboard is excessive (actual width closer to 4 feet); the 6.5-foot distance to east property line is insufficient (actual distance closer to 11 feet); also correct "Alley" to "Ash Avenue". 2. Billboard Notes (#7; 1st Bullet): add removal of horizontal light arm supports. 3. Billboard Notes (#7; 3rd Bullet): indicate lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 4. Billboard Notes (#8): amend "modification" to "modification and repair". 5. Title Block: amend title to "Lighting Modification & Repair Site Plan". Electrical Plan Sheet (Sheet 2 of 3) 1. Billboard Notes (#4): add "Approximate Center of Footprint". 2. Billboard Notes (#7; 1st Paragraph): add removal of horizontal light arm supports. 3. Billboard Notes (#7; 2nd Paragraph): indicate lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 4. Electrical Riser Diagram: indicate the size, type, and number of conductors between the ballast and the lamp sockets. 5. Electrical Riser Diagram & Elevation: clarify why ¾" EMT conduit is being shown where ½" EMT conduit should be adequate for a single ballast/single fixture application; if changed to ½" EMT on plans, conform same in Billboard Notes on Sheets 1 & 2 and Back View on Sheet 3. 6. Electrical Riser Diagram: indicate the manufacturer and model number for the replacement meter socket. 7. Title Block: add appropriate title in title space (e.g., "Lighting Modification & Repair Plan"). Overhead Fluorescent Lighting (Sheet 3 of 3) 1. End View: designate the two angle iron metal halide lighting supports on back side of uprights to be removed. 2. Mounting Detail: clarify the substitution of pole spikes for the screws indicated in the engineer's letter (Exhibit 8 of the Stipulation). 3. End View: add dimension for distance that fixture extends horizontally from point of attachment. 4. Back View: add length dimension for the light fixture. 5. Add the street address and COT ID# to the plan sheet. 6. Add engineer's stamp to the plan sheet [Note: it would be preferable for the engineer to incorporate the details from this sheet into the electrical plan sheet]. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
04/22/2010 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
04/22/2010 | SUE REEVES | REJECT SHELF | Completed |