Permit Review Detail
Review Status: Completed
Review Details: BILLBOARD-BLDG/ELEC
Permit Number - T10EL00459
Review Name: BILLBOARD-BLDG/ELEC
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/04/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
03/04/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
03/15/2010 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | 3/17/10 Amended comments below. AMENDED COMMENTS ON LIGHTING MODIFICATION & REPAIR SUBMITTAL FOR CLEAR CHANNEL BILLBOARD COT ID #471 AT 2844 NORTH 1ST AVENUE Lighting Removal, Modification and/or Replacement Site Plan (Sheet 1 of 3) 1. Billboard Notes (#7; 3rd Bullet): add lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 2. Billboard Notes (#8): amend "modification" to "modification and repair". 3. Title Block: amend title to "Lighting Modification & Repair Site Plan". Electrical Plan Sheet (Sheet 2 of 3) 1. Add notation that reads "No parts or components are to be removed, installed, replaced, or reinstalled except as indicated". 2. Billboard Notes (#4): add "Approximate Center of Footprint" 3. Billboard Notes (#7; 2nd Paragraph): indicate the lamp manufacturer and conform the lamp model number and the initial lumen rating to that shown on Sheet 3. 4. Electrical Riser Diagram: indicate the size, type, and number of conductors between the ballast and the lamp sockets. 5. Electrical Riser Diagram: Electrical Riser Diagram: clarify why ¾" EMT conduit is being shown where ½" EMT conduit should be adequate for a single ballast/single fixture application; if changed to ½" EMT on plans, conform same in Billboard Notes on Sheets 1 & 2 (#7; 4th Bullet/3rd Paragraph) and Back View on Sheet 3. 6. Electrical Riser Diagram: clarify the nature of the box depicted below the ballast. 7. Partial Plan View: describe on plan the existing & replacement controls to be replaced; also include replacement in scope of work (Billboard Note #7). 8. Title Block: add appropriate title in title space ("Lighting Modification & Repair Plan"). Overhead Fluorescent Lighting (Sheet 3 of 3) 1. Description of Existing Lamp: indicate lamp manufacturer. 2. End View: designate the two angle iron metal halide lighting supports on back side of uprights to be removed. 3. Mounting Detail: clarify the substitution of pole spikes for the screws indicated in the engineer's letter (Exhibit 8 of the Stipulation). 4. End View: add dimension for distance that fixture extends horizontally from point of attachment. 5. Back View: add length dimension for the light fixture. 6. Add the street address and COT ID# to the plan sheet. 7. The sheet needs to be stamped by the engineer [Note: it would be preferable for the engineer to incorporate the details from this sheet into the electrical plan sheet]. Original 3/12/10 comments below. COMMENTS ON LIGHTING DEMOLITION/ REPLACEMENT SUBMITTAL FOR CLEAR CHANNEL BILLBOARD COT ID #471 AT 2844 NORTH 1ST AVENUE Billboard Modification Site Plan (Sheet 1 of 3) No comments. Electrical Plan Sheet (Sheet 2 of 3) 1. Add notation that reads "No parts or components are to be removed, installed, replaced, or reinstalled except as shown on plans". 2. Billboard Notes (#4): indicate the manufacturer of the lamp. [Note: the model number is unique to Sylvania] 3. Billboard Notes (#7): clarify the initial lumen rating (8434 shown as compared to 8430 on Sheet 3). 4. Electrical Riser Diagram: indicate the size, type, and number of conductors between the ballast and the lamp sockets. 5. Electrical Riser Diagram: clarify why ½" EMT conduit is being upgraded to ¾" EMT conduit; if changed to ½" on plans, conform same on Sheet 1 and Sheet 3 [Note: if six #14 or #18 wires per ballast are used as in respective previous fluorescent submittals, then ½" conduit is adequate for this single ballast application] 6. Electrical Riser Diagram: clarify the nature of the box depicted below the ballast. 7. Partial Plan View: describe on plan the existing & replacement controls to be replaced; also include replacement in scope of work (Billboard Note #7). 8. Title Block: add appropriate title in title space (e.g., "Lighting Demolition & Replacement Plan"). Overhead Fluorescent Lighting (Sheet 3 of 3) 1. Description of Existing Lamp: indicate lamp manufacturer. 2. End View: designate the two angle iron metal halide lighting supports on back side of uprights to be removed. 3. Mounting Detail: clarify the substitution of pole spikes for the screws indicated in the engineer's letter (Exhibit 8 of the Stipulation). 4. End View: add dimension for distance that fixture extends horizontally from point of attachment. 5. Back View: add length dimension for the light fixture. 6. Add the street address and COT ID# to the plan sheet. 7. The sheet needs to be stamped by the engineer [Note: it would be preferable for the engineer to incorporate the details from this sheet into the electrical plan sheet]. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/24/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
03/24/2010 | SUE REEVES | REJECT SHELF | Completed |