Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T10CM03509
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2011 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 01/05/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 01/05/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Clarify the purpose of the 3-compartment sink located in room 184 with regard to the waste connections. If each compartment is used to process food or ice for human consumption or to sanitize food-serving plates and utensils, an indirect connection is appropriate; otherwise, provide direct connections to the sewer system. Reference: Sections 304.0, 704.3, and 801.2, UPC 2006. 2. Provide upper terminal cleanouts on horizontal drainage pipe over 5 feet in length (horizontal drain lines serving sinks and urinals require cleanouts regardless of length). Reference: Section 707.4, UPC 2006. 3. Clarify the installation of the floor drain in room 185. Does the "existing waste piping" include a vent and a cleanout? Reference: Sections 103.2.3, 707.4, and 901.0, UPC 2006. |
| 01/05/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | The new dehumidifying unit (DHU-9) does not introduce any outdoor air into the building. Show that adequate ventilation is still being supplied to the building. Reference: Sections 102.4 and 401.2, IMC 2006 and Section 1202.2.1, UBC 1994. |
| 01/11/2011 | GERRY KOZIOL | WWM | REVIEW | Denied | NEED WW CREDIT EVALUATION FROM 5TH FLOOR. |
| 01/14/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/21/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
| 12/21/2010 | RONALD BROWN | ZONING HC | REVIEW | Passed | Reference Building Comments |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/19/2011 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 01/19/2011 | SUE REEVES | REJECT SHELF | Completed |