Permit Number: T10CM03487
Parcel: 141100080

Address:
7501 S KOLB RD

Review Status: Completed

Review Details: CELL TOWER/ANTENNAS

Permit Number - T10CM03487
Review Name: CELL TOWER/ANTENNAS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/10/2011 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: T10CM03487
7501 S KOLB RD (1st Review)

TRANSMITTAL DATE: January 10, 2011

1. The Cell Tower plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Provide documentation from Tucson Police Department that PROCEDUAL CONTITION #5 has been met.

3. Per LAND USE COMPATABILITY comment 13 a ten (10) foot wide landscape buffer is required around the perimeter of the required site wall. Show the ten (10) foot wide landsacpe buffer on the site plan. Zoning acknowledges the letter dated April 26, 2010 from Michael W. Wyndken that allows for the existing natural vegetation to serve as the buffer. This letter does not eleminate the requirement for the ten (10) foot buffer around the perimeter wall. This buffer must be entirely on site.

4. Zoning will re-review the Cell Tower plan on the next submittal to insure compliance. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\celltower\t10cm03487.doc
01/31/2011 BRIAN HEFFERNAN COMMUNICATIONS REVIEW Denied NEED COMMUNICATIONS INFO SHEET
12/17/2010 DAVE MANN FIRE REVIEW Approved
12/22/2010 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. GENERAL: PROVIDE FULL SIZED DRAWINGS SIGNED AND SEALED BY THE ENGINEER OF RECORD DEPICTING THE MONOPOLE FOUNDATION AND REINFORCING, INCLUDING PIER DIAMETER, DEPTH, VERTICAL REINFORCING, TIES, AND THE NEW EQUIPMENT SLAB.
2. GENERAL: PROVIDE FULL SIZED DRAWINGS SIGNED AND SEALED BY THE ENGINEER OF RECORD DEPICTING THE MONOPOLE, CRITICAL ELEVATIONS OF ANTENNA ARRAYS AND POLE SPLICES, CONNECTION OF THE ANTENNA BRACKETS TO THE POLE, CONNECTION AT THE POLE SPLICES, MONOPOLE BASE PLATE AND ANCHOR BOLT DETAILS.
3. GENERAL: PROVIDE A DETAILED COST ANALYSIS FOR ALL MATERIALS AND LABOR OF THIS PROJECT, INCLUDING THE MONOPOLE, ANTENNA ARRAYS AND BRACKETS, MONOPOLE FOUNDATION, NEW EQUIPMENT CONCRETE SLAB, NEW 8' TALL MASONRY WALL AND FOOTING, NEW ICE BRIDGE, NEW EQUIPMENT CABINETS, NEW PREFABRICATED EQUIPMENT SHELTER, AND NEW SWING GATES.
4. GENERAL: WHERE IS THE PREFABRICATED EQUIPMENT SHELTER LOCATED? SHOW IT ON THE DRAWINGS.
5. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
12/27/2010 PETER MCLAUGHLIN PLANNING-CITY HALL REVIEW Approved
12/29/2010 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Approved
12/30/2010 ELIZABETH EBERBACH ENGINEERING REVIEW Denied DATE: January 6, 2011
SUBJECT: UofA Tech Park Cell Tower Review submittal
LOCATION: 7501 S KOLB RD, T15S R15E Secs20, 21, 27, & 28, Ward 4
REVIEWER: Elizabeth Leibold, PE
ACTIVITIES: T10CM03487
FLOODPLAIN: Balanced Basin Management Plan, FIRM 2855K

SUMMARY: The subject property and proposed cell tower improvements are located within a Zone X-shaded 500-yr floodplain as shown on the Flood Insurance Rate Map (FIRM), Community- Panel No. 04019C-2855K, effective date February 8, 1999. Engineering Division of the City of Tucson Planning & Development Services Department has received and reviewed the submittal package. Engineering does not recommend approval of the plans until the following comments are addressed.

COMMENTS:
1) SE-09-17 (Ord.10761): Show compliance of special exception conditions. In response letter and on plans with notes or on planview, explain how project is in compliance for items 8, 13, 14, & 16.
2) DS Sec.11-01: Show at minimum 2-ft offset from east property boundary.
3) DS Sec.10-02.2.3.1.5.G: Provide copy of lease agreement or license agreement for parcel owned by Az Board of Regents.


Submit 2 copies of the supporting documentation, and response letter. I can be reached at 837-4934 if you have questions.

Elizabeth Leibold, PE, CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services Department

Final Status

Task End Date Reviewer's Name Type of Review Description
05/12/2011 CINDY AGUILAR OUT TO CUSTOMER Completed
05/12/2011 SUE REEVES REJECT SHELF Completed