Permit Review Detail
Review Status: Active
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T10CM03410
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Active
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/09/2010 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T10CM03410 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2005 National Electrical Code and Arizona Revised Statutes. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. GENERAL NOTES: " Provide ΒΌ" = 1' scaled drawings with legible notation (minimum 3/32" lettering). Consider submittals on larger paper size. STRUCTURAL PLANS: 1. The roof structure may not be suitable for additional dead loading without modification, R301.1 & Table R802.5.1. Clarify if the porch 2 x 6 @ 24" rafters are spanning 13 feet 4 inches between bearing points requires reinforcement. Also, show the span and size of load bearing beams. Provide a design for supporting the required dead load along with a 20 PSF live load. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
12/13/2010 | SUE REEVES | REJECT SHELF | RECEIVED |