Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Permit Number - T10CM03286
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/23/2010 | DAVID RIVERA | ZONING | REVIEW | Denied | DSD Zoning Review Transmittal TO: Planning and Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: T10CM03286 2544 N Fair Oaks TRANSMITTAL DATE: November 23, 2010 Proposed project includes Front Porch (street side) and Carport along the South property line. COMMENTS: Site Plan OK D.D.O. required for: North and South building setbacks (interior side yards) 1. Per LUC Section 3.2.6.4 R-2 Zone, Development Designator "I", Perimeter Yard Indicator "AA" the required perimeter yard setback is 6'-0" or 2/3 the height of the exterior wall. Perimeter yard setback to proposed porch to the north property line is based on a wall height of 8'-0", required setback is 6'-0", 4'-0" provided. 2. Per LUC Section 3.2.6.4 R-2 Zone, Development Designator "I", Perimeter Yard Indicator "AA" the required perimeter yard setback is 6'-0" or 2/3 the height of the exterior wall. Perimeter yard setback to carport to the south property line is based on a wall height of 8'-0", required setback is 6'-0", 4'-0" provided. 3. If you have any questions about this transmittal, please contact me at David.Rivera@tucsonaz.gov or (520) 837-4957 |
| 11/23/2010 | DROBEY1 | NPPO | REVIEW | Needs Review | |
| 11/23/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 11/23/2010 | DROBEY1 | ENGINEERING | REVIEW | Needs Review | |
| 12/21/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 12-22-10 Activity: T10CM03286 Address: 2544 N Fair Oaks Applicant: Jon Goff Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings and one set of the first submission for reference. All corrections and revisions shall be made on original tracings or finished reproducible set. Pencil and/or white out on final prints will not be acceptable. To expedite review, please cloud the originally submitted set with red ink and limit clouding on final set. Ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. STRUCTURAL / FRAMING PLAN: 2. When the roof pitch is less than 3:12, design structural members that support rafters and joists as beams (hip rafters), R802.3. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/27/2010 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 12/27/2010 | SUE REEVES | REJECT SHELF | Completed |