Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10CM03271
Parcel: 125041110

Address:
2008 E 1ST ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM

Permit Number - T10CM03271
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/19/2010 TERRY STEVENS ZONING REVIEW Denied This property at this time is nonconforming and therefore expansions are not allowed. Zoning acknowledges that a site/development plan is in review, approval of the expansions must wait until approval of site/ development plan.
11/24/2010 GERRY KOZIOL WWM REVIEW Approved
11/29/2010 ANDREW CONNOR NPPO REVIEW Passed
12/10/2010 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied T10CM03271
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007 and the 2006 UPC with amendments on 7/10/2007. For initial construction: Effective 1/1/2007 the Inclusive Home Design; starting 3/1/2009 Solar Water Preparation and 7/1/2009 Solar Photo-Voltaic Preparation are required for all new SFR and duplex plans. Show the code references on the plans. Amendments to adopted codes are at the City web-site http://www.tucsonaz.gov: Planning, Building, & Business; under the Building topic; Building Ordinances and Codes; Building Codes

SITE PLAN:

1. Indicate the location of buildings, utility meters and gas, water and sewer lines from property line to building, R106.1.1.

STRUCTURAL PLANS:

1. Show a standard Glu-lam beam size on the Framing Plan, R301.1. The 3-1/8" x 10.5" size is an available size.

SECTIONS - DETAILS:

1. Clarify the pantry and laundry wall keynote on the Floor Plan, sheet A1.0. Keynote #5 rather than #7.
2. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c ceiling framing, IRC table R702.3.5 footnote d.
3. Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, R702.4.2.

PLUMBING PLANS:

1. Provide water hammer arresters wherever quick-closing valves are installed in a water distribution system. The devices should conform to ASSE 1010-2004. Water hammer arresters are required for clothes washer, dishwasher and refrigerator water connections, P2903.5.
2. Provide pipe sizes in compliance with the code, P2903.7. Show a 1" service pipe diameter, between the meter and point where down stream demand does not exceed the maximum fixture units for the 3/4" pipe, P2903.6.
3. Clarify the point of connection of the new cold water line to existing service pipes. Any pipe segments providing water to other dwellings must be sized for the total demand for verifying control of excessive water flow rates. Existing shared water pipes may require replacement to larger sizes, P2903.7.
4. Provide gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). The 1" service pipe is undersized for the demand and the 175' length shown.

ELECTRICAL PLANS:

1. Show locations of smoke alarm, R313. Notate that all smoke alarms must be interconnected with a power source from the building wiring, and be equipped with battery backup. Include an entry on the panel schedule..
2. Smoke alarms are required outside each separate sleeping area, R313.2. Show a smoke alarm on the outside of the bedroom door.
3. Provide the dwelling electrical load calculation for verifying the service panel size of 100A, E3502.2.
4. Provide a panel schedule showing the breaker size of each circuit, E3602.2. Include #6, 8, 10, 12 & 14.
5. Show one 20 AMP branch circuit on the panel schedule for the laundry area; this circuit may not serve other locations, E3603.3 and 3801.8.
6. Show a GFCI receptacle outlet on the same level within 25' of exterior HVAC equipment, E3801.11.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
12/27/2010 DELMA ROBEY OUT TO CUSTOMER Completed
12/27/2010 SUE REEVES REJECT SHELF Completed