Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T10CM03165
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/10/2010 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 11/15/2010 | DAVE MANN | FIRE | REVIEW | Denied | Fire Comments: Fire access roads are required per IFC Section 503 for all structures over 150 feet fro the street. The new fire hydrant needs to be relocated so all portions of the buildings have a less than 300 foot hose lay from it. |
| 11/16/2010 | RONALD BROWN | ZONING HC | REVIEW | Denied | Reference Building Comments |
| 11/16/2010 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. Need approved site plan. 2. All documents must be the same size 3. Please identify all buildings to be constructed on the site plan and refer all the following plans to that assigned building identity. 4. Please provide a cover sheet with title of project, Drawing Index, building code data for all new buildings and code compliance listing. 5. Please present the construction drawings in an organized and sequential format as per industry standards. Reference 2006 IBC, Section 106 Construction Documents. Provide two complete sets for permit review. 6. Please provide a statement of special inspections and the completed certifications for approval. 7. Please organize the specifications into one Structural Calculation booklet with an accompanying index. Please provide two copies. END OF REVIEW |
| 11/18/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | No plumbing systems proposed. |
| 11/18/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | No mechanical systems proposed. |
| 11/18/2010 | ROBERT SHERRY | WATER | REVIEW | Denied | If the property is served by a public water supply, show the location and size of the water meter and reduced pressure backflow prevention assembly. Reduced pressure backflow prevention assemblies are required at the water meter for properties that have active private wells. Reference: COT Backflow Prevention Ordinance, http://www.tucsonaz.gov/water/docs/backflow-ord.pdf |
| 11/24/2010 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | See comments for site plan. |
| 11/30/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
| 12/06/2010 | GERRY KOZIOL | WWM | REVIEW | Denied | cannot approve until septic permit is approved |
| 12/07/2010 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | The bldg. plans cannot be approved prior to the FUP, Site or Grading plans. |
| 12/09/2010 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |