| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Comment not resolved; the temperature extender (Watts model N170L) is not listed for limiting the water temperature at fixtures. Quoting the installation document for the Watts N170L, "Watts Hot Water Extender Tempering Valves cannot be used for tempering water temperature at fixtures. Severe bodily injury (i.e., scalding or chilling) and/or death may result depending upon system water pressure changes and/or supply water temperature changes. ASSE standard 1016 listed devices such as Watts Series MMV and L111 valves should be used at fixtures to prevent possible injury." Reference: Sections 310.4 and 413.1, UPC 2006 and Section 504.3, IECC 2006. |
| 01/04/2011 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 01/05/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/23/2010 | ERIC NEWCOMB | ZONE H/C | REVIEW | Approved | 1. SEE BUILDING COMMENTS. |
| 12/23/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | 1. SEE PREVIOUS COMMENT 1. APPEAL TO THE BUILDING OFFICIAL WAS DENIED. REVISE THE FLOOR PLAN ON SHEET A-2.1 TO MEET THE MANEUVERING CLEARANCE OF 18" MINIMUM FOR THE FRONT APPROACH ON THE PULL SIDE OF THE DOOR PER ICC/ANSI A117.1-2003 FIGURE 404.2.3.1(a). 2. SEE PREVIOUS COMMENT 2. APPEAL TO THE BUILDING OFFICIAL WAS DENIED. REVISE THE FLOOR PLAN ON SHEET D-2 TO MEET THE MANEUVERING CLEARANCE OF 18" MINIMUM FOR THE FRONT APPROACH ON THE PULL SIDE OF THE DOOR PER ICC/ANSI A117.1-2003 FIGURE 404.2.3.1(a). |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/06/2011 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 01/06/2011 | SUE REEVES | REJECT SHELF | Completed |