Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T10CM03081
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/04/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
| 11/09/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET A-2.1; FLOOR PLAN: IN THE MEN'S AND WOMEN'S RESTROOMS, A MANEUVERING CLEARANCE OF 18" MINIMUM IS REQUIRED FOR THE FRONT APPROACH ON THE PULL SIDE OF THE DOOR PER ICC/ANSI A117.1-2003 FIGURE 404.2.3.1(a). VERIFY. 2. SHEET D-2; TOILET ROOM PLAN: SEE NOTE 1. 3. SHEET D-3; SECTION 9: ADDRESS THE CONNECTION OF THE CANOPY TO THE WALL (PROVIDE THE SIZE, QUANTITY, AND SPACING OF THE ANCHORS, OR "PER MANUFACTURER") . 4. SHEET D-3; SECTION 12: THE BLOCKING INDICATED ON THE SECTION DOES NOT MATCH THE BLOCKING ON THE ENLARGED DETAIL. VERIFY. 5. SHEET D-3; SECTION 12: ADDRESS THE CONNECTION OF THE CANOPY TO THE WALL (PROVIDE THE SIZE, QUANTITY, AND SPACING OF THE ANCHORS, OR "PER MANUFACTURER"). 6. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 11/10/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Denied | 1. SEE BUILDING COMMENTS. |
| 11/17/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Show how the temperature of the hot water supply to the public lavatories is to be controlled. Reference: Section 413.1, UPC 2006 and Section 504.3, IECC 2006. 2. Show how the drainage piping is to be "adapted" for the new location of the lavatories. Reference: Section 103.2.3, UPC 2006. |
| 11/17/2010 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 11/17/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 11/23/2010 | GERRY KOZIOL | WWM | REVIEW | Denied | need to provide complete plumbing fixture schedule to include the total # of all fixtures connected to the sanitary sewer system (including all drains) with waste pipe sizes. provide plumbing plan with grease trap/interceptor and calclations. need evaluation for connection fee credits by WW Maps & Records- 5th floor PWB- 740-6606 |
| 11/29/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | PROJECT: T10CM03081 6872 E TANQUE VERDE RD KFC REMODEL 1. What are the the new fixtures shown on sheet A-3 being connected to ? Ray T Majuta, PDSD,City of Tucson, Elect Pln Ck, 11/30/10 Ray.Majuta@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/02/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 12/02/2010 | SUE REEVES | REJECT SHELF | Completed |