Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T10CM02909
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/11/2011 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | T10CM002909 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2005 National Electrical Code and Arizona Revised Statutes. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. GENERAL NOTES: 1. Provide manufacturer specification sheets for the mounting hardware. 2. Identify the means of battery terminal protection, NEC 690.71. 3. Provide a ΒΌ" scale plan drawing of the framing structure including the existing load carrying dwelling wall. STRUCTURAL PLANS: 1. Provide complete framing information for determining load carrying capacity of the structure supporting a collector group including fasteners and connections to existing structures. Show existing beam sizes over door or window opening if the proposed structure is placed over an existing opening, IRC M1401. DIAGRAMS / CALCULATIONS 1. Provide an up-lift calculation demonstrating the wind load supporting capability, R301.1. Show the total number and spacing of connection bolts. 2. Show module data voltage and amperage consistent with the manufacturer's specification. 3. Show the maximum Photovoltaic System Voltage calculation (Voc x 1.13) NEC 690.7 and Table 690.7 (16 degrees F lowest ambient). 4. Clarify the line diagrams for connection points with acceptably sized terminals. Indentify the DC Disconnect Box model with UL listing. 5. Show conductor sizes between each terminal point including between DC disconnect and AC Service disconnect with supporting voltage and amperage calculations. Oversized conductors must fix available equipment terminal sizes. 6. Show Ground Fault protection for the DC roof mounted arrays, NEC 690.5. 7. Show a continuous Grounding Electrode Conductor connected to the grounding electrode. (Reference NEC 250.64 (C), 250.160. NOTES / SPECIFICATIONS 1. Provide line side taps in compliance with NEC 230.46. 2. Show all equipment with listings by an Independent Testing Agency including the charging equipment and batteries. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/21/2011 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 03/21/2011 | SUE REEVES | REJECT SHELF | Completed |