Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10CM02746
Parcel: 11309363B

Address:
1245 E COPPER ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T10CM02746
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/12/2010 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 10-12-2010
Activity: T10CM02746
Address: 1245 E Copper St
Applicant: Martin Yoklic

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings and one set of the first submission for reference. All corrections and revisions shall be made on original tracings or finished reproducible set. Pencil and/or white out on final prints will not be acceptable. To expedite review, please cloud the originally submitted set with red ink and limit clouding on final set. Ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.
2. Specify accurate scale of drawings (sheet 6)

FLOOR PLAN:
3. Specify all door sizes on floor plan,

STRUCTURAL / FRAMING PLAN:
4. Specify continuous structural sheathing and show it on the wall section OR provide a complete braced wall panel layout showing panels at the ends (within 12.5') of all wall lines and additional panels centered at least every 25' between, Table R602.10.1. All exterior wall lines shall be braced and parallel interior wall lines shall be braced at intervals not exceeding 35' from exterior wall lines, R403.1.6, R602.10.1.1, R602.10.8.
5. Specify existing ridge beam and ceiling beam sizes, R802.1.
6. Provide uplift resistance for roof framing (H2.5) R802.11.1.

PLUMBING PLAN:
7. Provide manufacturer's cut sheet for the proposed water heater, P2608.2.

MECHANICAL PLAN:
8. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1.

ELECTRICAL PLAN:
9. Fixtures installed over a shower or bathtub must be approved for use in wet area, E3903.8.
10. Show exterior receptacles with GFCI protection, E3802.
11. Specify the existing circuits on the panel schedule, E3304.11, E3606.2.
12. Clarify the existing electrical service or if this permit includes an upgrade/relocation (panel is located on a wall that hasn't been built yet).

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/18/2010 DELMA ROBEY OUT TO CUSTOMER Completed
10/18/2010 SUE REEVES REJECT SHELF Completed