Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T10CM02678
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/14/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 10/22/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 10-25-10 Activity: T10CM02678 Address: T10CM02678 Applicant: Gerstenfeld Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings and one set of the first submission for reference. All corrections and revisions shall be made on original tracings or finished reproducible set. Pencil and/or white out on final prints will not be acceptable. To expedite review, please cloud the originally submitted set with red ink and limit clouding on final set. Ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Any architect and/or engineer involved in the design of the structure shall seal the related new or revised sheets of plans including details and calculations in accordance with the rules of the State Board of Technical Registration. FLOOR PLAN: 3. Specify safety glazing in hazardous locations (within 24" of doorways), R308.4. 4. Specify fiber-cement board backing in tub/shower enclosures, R307.2, R702.4.2. FOUNDATION PLAN: 5. Specify foundation hold-downs for alternate brace wall panels that have minimum uplift capacity of 1800 lbs (PAHD42 is insufficient), R602.10.6. 6. Provide a note for termite treatment, R320 as amended. PLUMBING PLAN: 7. Provide water supply piping plan and include a fixture unit schedule for all plumbing fixtures served by the water meter in question as well as the lowest available pressure and the maximum developed length, P2903.7. 8. Note and specify all piping materials, P2608.2. MECHANICAL PLAN: 9. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1. ELECTRICAL PLAN: 10. Provide an electrical riser diagram with grounding method and bonding to metallic piping. Provide feeder sizes according to the proposed load, E3303, E3507, E3604.3. 11. Correct electrical load calculations for determining the service panel size (40% reduction may not be applied to HVAC or subpanel), E3502.2. 12. Bathrooms require a separate 20-amp circuit, E3603.4, E3801.6. 13. Bedroom outlets shall be protected with combination-type arc-fault breakers (receptacles, lights, and smoke detectors), E3802.12. 14. Provide two or more 2O-amp small appliance circuits to serve counter spaces. Such circuits shall be GFCI protected and shall not serve other rooms (except breakfast areas, pantries, etc.), E3801.3. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/26/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 10/26/2010 | SUE REEVES | REJECT SHELF | Completed |