Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T10CM02635
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/22/2010 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Swan Park Access & Playground Improvements T10CM02635 Site Plan (2nd Review) TRANSMITTAL DATE: November 22, 2010 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the entire site. 2. This comment was not fully addressed. Clearly show the lot lines (property boundaries) on the site plan. The west dimension appears to be incorrect. Per the subdivision plat and the Assessor's Record Map this dimension should be 58.22'. Also based on the subdivision plat and the Assessor's Record Map there is no alley along the north side of the park, remove that reference from the plan. D.S. 2-02.2.1.A.5 Show the lot lines and provide lot dimensions and bearings on the site plan. 3. Until comment 2 above has been addressed perimeter yard setbacks cannot be verified. Per LUC Section 3.2.6.5.A the street perimeter yard is measured from the street property line not the back of sidewalk. D.S. 2-02.2.1.A.7 Provide setback dimensions to the north, south and east property lines on the site plan. 4. As no vehicle parking is provided bicycle parking is not required. 5. The proposed passenger loading zone located within the right-of-way (ROW) will need to be approved by COT Transportation Department prior to approval of the site plan. Contact Jose Ortiz @837-6730 or email Jose.Ortiz@tucsonaz.gov and provide documentation. 6. Depending on how all comments are addressed addition comments may be forth coming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t10cm02635 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan. |
| 11/22/2010 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | November 23, 2010 T10CM02635 Swan Park Play Structures 1. The site and adjacent rights-of-way must be fully dimensioned. Provide dimensions from the center line to the existing and proposed curb. Also tie the project to the street monument system 2. Provide estimated cut and fill quantities for this project. Even if all of the excavated soil is redistributed about the site, the estimated quantities must be provided. 3. Provide written permission from the Department of Transportation for the use of the street for the loading area. 4. The area along the north boundary of this property has historically been used for utility and solid waste access. Explain how this will be addressed. Water, sewer and electrical lines serving the adjacent residences are in this area. (Note that the area is not dedicated as alley but consists of an easement across the residential properties and an area used for this purpose for many years but for which no easement record is noted.) |
| 12/06/2010 | RONALD BROWN | ADA | REVIEW | Approved | |
| 12/06/2010 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approv-Cond | Ensure that all Engineering and Zoning comments and concerns are addressed |
| 12/06/2010 | ANDREW CONNOR | NPPO | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/07/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 12/07/2010 | SUE REEVES | REJECT SHELF | Completed |