Permit Number: T10CM02635
Parcel: 130152800

Address:
1700 S SWAN RD

Review Status: Completed

Review Details: SITE

Permit Number - T10CM02635
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2010 RONALD BROWN ZONING HC REVIEW Passed
09/23/2010 MARTIN BROWN FIRE REVIEW Approved
09/23/2010 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Swan Park Access & Playground Improvements
T10CM02635
Site Plan (1st Review)

TRANSMITTAL DATE: September 23, 2010

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the entire site.

2. D.S. 2-02.2.1.A The site plan should be drawn at a standard engineering scale no larger than l" = 60' not an architectural scale.

3. D.S. 2-02.2.1.A.2 Provide a property description, legal description, on the site plan.

4. D.S. 2-02.2.1.A.5 Show the lot lines and provide lot dimensions and bearings on the site plan.

5. D.S. 2-02.2.1.A.6 Provide the height of the proposed shade structure on the site plan.

6. D.S. 2-02.2.1.A.7 Provide setback dimensions to the north, south and east property lines on the site plan.

7. D.S. 2-02.2.1.A.9 As it appears that accessible parking is provided within the right-of-way for this project than two (2) Class 2 bicycle parking spaces are required for this site. Provide a detail that meets the requirements of D.S. 2-09.0.

8. D.S. 2-02.2.1.A.19 Provide a dimensioned right-of-way for Venice Ave.

9. D.S. 2-02.2.1.A.28 Provide the existing zoning of parcel and adjacent parcels, including those across streets and alleys.

10. D.S. 2-02.2.1.A.31 Provide the existing and proposed use on the site plan. The proposed use should be listed as "NEIGHBORHOOD RECREATION "12", SUBJECT TO: SEC. 3.5.13.2 AND SEC. 3.5.13.3"
11.

12. D.S. 2-02.2.1.A.32 Show the refuse container locations on the plan.

13. Depending on how all comments are addressed addition comments may be forth coming.
If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t10cm02635

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan.
09/29/2010 RBROWN1 ADA REVIEW Denied 1. The entry is not accessible. There are two accessible parking signs indicating reserved for accessible parking. The parking area available is not sufficient for accessible parking spaces, too small. The entance layout appears to be great a passenger loading zone but it is not designed with an accessible passenger loading zone. Please redesign the loading and include an accessible passenger loading zone as per ADAAG, Section 4.6.
2. If the seating leave out at the Picnic Table is for wheelchair persons, please identify it with the international symbol painted on the concrete surface at the space.
END OF REVIEW
10/13/2010 LOREN MAKUS ENGINEERING REVIEW Denied October 13, 2010
T10CM02635
Swan Park Play Structures


1. Provide a complete site plan of the site, including adjacent parcels that function as a single development. The site and adjacent rights-of-way must be fully dimensioned.
2. The address and parcel code for this project is for the established/developed part of Swan Park. The permit must be revised to apply to the correct parcel.
3. Clearly indicate the location of all facilities and development on the plan.
4. Provide estimated cut and fill quantities for this project.
5. The area along the north boundary of this property has historically been used for utility and solid waste access. Explain how this will be addressed. Water, sewer and electrical lines serving the adjacent residences are in this area.
6. Show the limits of the flood hazard area along Swan Park Wash.
10/14/2010 ANDREW CONNOR LANDSCAPE REVIEW Denied Show the limits of the flood hazard area along Swan Park Wash.

Ensure that all Engineering and Zoning comments and concerns are addressed
10/15/2010 ANDREW CONNOR NPPO REVIEW Denied Show the limits of the flood hazard area along Swan Park Wash.

Ensure that all Engineering and Zoning comments and concerns are addressed.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/18/2010 CINDY AGUILAR OUT TO CUSTOMER Completed