Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10CM02542
Parcel: 136126340

Address:
9909 E CREEK ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T10CM02542
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/27/2010 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 9-28-10
Activity: T10CM02542
Address: 9909 E Creek St
Applicant: Stanley Listzwan

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings and one set of the first submission for reference. All corrections and revisions shall be made on original tracings or finished reproducible set. Pencil and/or white out on final prints will not be acceptable. To expedite review, please cloud the originally submitted set with red ink and limit clouding on final set. Ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

FLOOR PLAN:
2. Revise shower wall covering note to reflect the currently adopted code. Excerpt provided (702.4.2) is from the 2003 IRC. Water-resistant gypsum is no longer acceptable.

STRUCTURAL / FRAMING PLAN:
3. Specify all header sizes consistent with Table 502.5(1) or specify size of steel lintels.

SECTIONS - DETAILS:
4. Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d.

ELECTRICAL PLAN:
5. Provide legible cut sheet information regarding whirlpool bathtub.
6. Provide gfci protected receptacle to serve whirlpool bathtub and access panel, E4109.

INTERNATIONAL ENERGY CONSERVATION CODE:
7. The simplified prescribed energy values for ceilings is R=30, N1102.1.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review
10/08/2010 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
10/19/2010 CINDY AGUILAR OUT TO CUSTOMER Completed
10/19/2010 SUE REEVES REJECT SHELF Completed