Permit Review Detail
Review Status: Completed
Review Details: OTHER
Permit Number - T10CM02528
Review Name: OTHER
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/20/2010 | DAVID RIVERA | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: David Rivera Principal Planner PROJECT: T10CM02528 875 W. Miracle Mile Ghost Ranch - Office/Clubhouse Unit #1 TRANSMITTAL DATE: September 20, 2010 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. After reviewing and comparing the building package site plan and landscape plan with the previously approved site and landscape plans it is clear that there are some changes to the site and building one that must be addressed. Zoning is requesting that a revised site and landscape plan is submitted for review and approval for the proposed changes which include the square footage of building one and the redlined areas on sheet AS-1. 2. The square footage of building one (1) has changed from 1,600 square feet as listed on the approved site plan to 2,000 square feet per the info on sheet AS-1 and 2,024 per the dimensioned floor plan. While the additional square footage does not affect the overall development it is not accounted for in the approved site plan. Also the building height is listed as 9'-6" on sheet AS-1 which conflicts with the building elevations due to a flat roof not a gabled roof. Therefore prior to zoning approval of the building plans the site and landscape must be revised and re-approved. All conflicting information between the building plans and site plan must be revised. Please review the revised site plan and building plans to ensure consistency with the development information. The height of the parapet wall for building wall is dimensioned as 15 feet plus 6 inches from design grade. Based on this height the minimum building setback is 23.25 feet. The setback labeled on sheet AS-1 is 21'-10". A board of Adjustment variance will be required unless the building is moved back to provide the minimum setback requirement. 3. When submitting the revised site and landscape plans for review, include a cover letter explaining the changes that have been made. These are the changes noted as part of this zoning review, which will include any calculation changes. a. Cross walk location and access ramps at main entrance along Miracle Mile. b. Sidewalk and the access ramp at the corner of Fairview and Miracle Mile. c. Sidewalks, access ramps and crosswalk at the northwest entrance along Fairview. d. Crosswalks and access ramps between buildings 1 and 3. e. Relocation and addition of an additional HC parking adjacent to buildings 1 and 2. f. Sidewalks and relocation of the bicycle parking facilities from building 3 to building 4. g. Calculations for building square footage must be revised. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. C:\planning\idrive\cdrc\DSC\Ghostranch lodge units 1-12.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/13/2010 | SUE REEVES | OUT TO CUSTOMER | Completed |