Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10CM02519
Parcel: 10705126E

Review Status: Completed

Review Details: OTHER

Permit Number - T10CM02519
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2010 DAVID RIVERA ZONING REVIEW Denied FROM: David Rivera
Principal Planner

PROJECT: T10CM02519
875 W. Miracle Mile
Ghost Ranch - Three Unit Building - buildings 4 - 7

TRANSMITTAL DATE: September 20, 2010

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Review the square footage of building 4 - 7 based on the actual building dimensions labeled on sheet A-5.0. Ensure that the correct square footage has been listed on sheet AS-1. Please ensure that when calculating the square footages of the building that the outside dimensions are used and all non enclosed areas such as porches are not included. Carports are not part of the dwelling square footage but do count towards the lot coverage and should be listed as carport square footage where applicable. While the additional square footage does not increase the need for additional parking spaces it does affect the lot coverage and floor area ratios. The development criteria will have to be revised as required to match the actual per the floor plan dimensions.

I acknowledge the note for the replacement of existing windows but I'm not sure that this is what Jonathan had in mind. I believe but I admit I'm not clear myself if the note is intended for existing windows or was it to include the new ones. I have put in a call to Jonathan for some feed back but I am requesting that you (Paul) do the same and get a clarification.

2. After reviewing and comparing the building package site plan and landscape plan with the previously approved site and landscape plans it is clear that there are some changes to the site and building one that must be addressed. Zoning is requesting that a revised site and landscape plan is submitted for review and approval for the proposed changes which include the square footage of building one and the redlined areas on sheet AS-1.

3. When submitting the revised site and landscape plans for review, include a cover letter explaining the changes that have been made. These are the changes noted as part of this zoning review, which will include any calculation changes.

a. Cross walk location and access ramps at main entrance along Miracle Mile.

b. Sidewalk and the access ramp at the corner of Fairview and Miracle Mile.

c. Sidewalks, access ramps and crosswalk at the northwest entrance along Fairview.

d. Crosswalks and access ramps between buildings 1 and 3.

e. Relocation and addition of an additional HC parking adjacent to buildings 1 and 2.

f. Sidewalks and relocation of the bicycle parking facilities from building 3 to building 4.

g. Calculations for building square footage must be revised.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

C:\planning\idrive\cdrc\DSC\Ghostranch lodge units 1-12.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents

Final Status

Task End Date Reviewer's Name Type of Review Description
10/13/2010 SUE REEVES OUT TO CUSTOMER Completed