Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T10CM02353
Parcel: 125050770

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T10CM02353
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/03/2010 GERRY KOZIOL WWM REVIEW Approved
09/13/2010 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET S1.0; DETAIL 8: THE BASE PLATE AND ANCHOR BOLTS ON THE DRAWING DO NOT MATCH THE STRUCTURAL CALCULATIONS (PAGE 19). CLARIFY.
2. SHEET S1.0; DETAIL 10: PROVIDE THE FOOTING THICKNESS ON THE DETAIL.
3. SHEET S1.0; DETAIL 6: CALL OUT THE REINFORCING IN THE NEW FOOTING.
4. SHEET S1.0; DETAIL 8: PROVIDE A NOTE ON THE PLAN TO REMOVE THE EXISTING FOOTING AND SLAB AS REQUIRED AT THE NEW COLUMN FOOTING.
5. SHEET S1.0; DETAIL 10: THE DETAIL INDICATES NO EXISTING FOOTING IS TO BE REMOVED, WHILE THE PLAN INDICATES THE NEW FOOTING EXTENDS TO THE EXISTING WALL. CLARIFY.
6. SHEET S1.0; DETAIL 11: THE PLAN INDICATES A WOOD POST, WHILE THE DETAIL INDICATES A STEEL PIPE COLUMN. CLARIFY.
7. SHEET S2.0; DETAIL 2: REVISE THE ABBREVIATION FOR PLYWOOD.
8. SHEET S2.0; GENERAL FRAMING NOTES: NOTE 10 LISTS THE ROOF DEAD LOAD FOR THE FLOOR. REVISE.
9. SHEET S2.0; ROOF AND FIRST FLOOR FRAMING PLANS: PROVIDE A DETAIL INDICATING HOW THE 4X6 WOOD POSTS AT THE SECOND FLOOR BALCONY ARE CONNECTED TO THE MASONRY LINTEL BEAM BELOW.
10. SHEET S2.0; ROOF FRAMING PLAN: PROVIDE THE WOOD BEAM SIZES ON THE PLAN AT THE NORTH BALCONY.
11. SHEET S2.0; FIRST FLOOR FRAMING PLAN: THE DETAIL CUT 13/S3.0 AT THE INTERIOR PIPE COLUMN IS INCORRECT. REVISE (16/S3.0?).
12. SHEET S2.0; FIRST FLOOR FRAMING PLAN: THE DETAIL CUT 16/S3.0 AT THE WOOD BEAM CONNECTION TO THE GLU LAM BEAM IS INCORRECT. ADD A NEW DETAIL FOR THIS CONDITION.
13. SHEET S3.0; ELEVATION 7: NOTE 6 INDICATES HOLD DOWNS ARE ON THE FOUNDATION PLAN. THESE WERE NOT LOCATED. REVISE (PER STRUCTURAL CALCULATIONS).
14. SHEET S3.0; DETAIL 4: THIS DETAIL WAS NOT LOCATED ON THE ROOF FRAMING PLAN. VERIFY AND REVISE.
15. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
09/14/2010 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 9-12-10
Activity: T10CM02353
Address: 2406 E 4th St #2
Applicant: Alex Enoch

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.
2. Any architect and/or engineer involved in the design of the structure shall seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.
3. As of 6/12/2007 the City of Tucson has adopted the 2006 IRC. Remove references to the 2003 IRC or appeal to the Building Official for use.

SITE PLAN:
4. Show the location of the water supply line to unit #2, R106.1.1.

FLOOR PLANS:
5. Specify cement or fiber-cement board backing in tiled shower surrounds, R307.2, R702.4.2.

FOUNDATION PLANS:
6. Provide a note for termite treatment, R320 as amended.

PLUMBING PLAN:
7. Provide an accurate water supply fixture unit schedule (27.1 existing +5.7 proposed ? 29) P2903.7.
8. Provide note requiring that water hammer arrestors be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators.
9. Shower and tub/shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type.

ELECTRICAL PLAN:
10. Clarify circuit references to proposed panel, E3603.5 (layout and panel schedule indicate circuits are in panel A)
11. Kitchens and dining rooms require two or more 2O-amp circuits that supply power to the small appliance receptacles located along counter space. Such circuits shall be GFCI protected and shall not serve other rooms (except breakfast areas, pantries, etc.), E3801.3.
12. Bathroom receptacles require a separate 20-amp circuit, E3801.6 (may not share kitchen circuit).
13. Laundry rooms require at least one 20-amp circuit that shall serve no other outlets, E3603.3, 3801.8 (may not share kitchen circuit).
14. Provide a complete load calculation for the proposed load on the new panel (40% demand factor may not be applied and must include heating/cooling) E3604.3.
15. Provide two spaces in panel for all 220 receptacles located in garage area.

OUTDOOR LIGHTING CODE
16. The unshielded lumen allowance is part of the total lumen allowance (limit ? shielded + unshielded) OLC 3.1.2

INTERNATIONAL ENERGY CONSERVATION CODE:
17. Specify a "U" factor and solar heat gain coefficient of the windows and doors that meets or exceeds the requirements of N1102.1. The simplified prescribed energy value for climate zone 2B glazing and skylights is U=0.75, the default SHGC is 0.40.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
09/15/2010 CINDY AGUILAR OUT TO CUSTOMER Completed