Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TI ALL
Permit Number - T10CM02221
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/14/2011 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PREVIOUS COMMENT 2: SHEET C1; APPLICABLE CODES: REVISE THE ACCESSIBILITY CODE REFERENCE DATE. 2. PREVIOUS COMMENT 3: SHEET 1; EXISTING BUILDING: WITH THE BUILDING USE DESIGNATION OF "RESTAURANT", THIS IS NOT AN OCCUPANCY GROUP R. REVISE. 3. PREVIOUS COMMENT 8: SHEET 3; FLOOR PLAN: A NOTE AT THE WEST ENTRANCE (03) INDICATES "FURR OUT EXTERIOR WALLS 4" AND INSULATE AS PER SPECIFICATIONS". PROVIDE SPECIFICATIONS FOR THIS JOB. 4. PREVIOUS COMMENT 9: SHEET 3; FLOOR PLAN: A NOTE AT THE WEST BLOCK WALL INDICATES "PROVIDE VERTICAL AT ALL CORNERS, EDGES OF OPENINGS, AND END OF WALLS AS REQUIRED". ADD DETAILS TO THE DRAWINGS INDICATING THIS REINFORCING. 5. PREVIOUS COMMENT 13: SHEET 4; DIMENSION PLAN: PROVIDE A DIMENSION FOR THE CLEAR CORRIDOR WIDTH TO ENSURE REQUIREMENTS OF SECTION 1017.2 OF THE IBC ARE MET. 6. PREVIOUS COMMENT 18: SHEET 6; BOXED NOTE: THE SKYLIGHT GLAZING MATERIAL NOTE REFERENCES THE IRC (R308.6). REVISE. 7. PREVIOUS COMMENT 19: SHEET 6; BOXED NOTE: THE NAILING NOTE, FRAMING CONNECTORS, AND GYPSUM BOARD ALL REFERENCE IRC TABLES. REVISE. 8. PREVIOUS COMMENT 25: SHEET 7; DETAIL 5: INDICATE THE FOOTING IS 2'-0" SQUARE. 9. PREVIOUS COMMENT 36: SHEET 8; BOXED NOTE: THE ROOF VENTS NOTE REFERENCES THE IRC. REVISE. 10. PREVIOUS COMMENT 37: SHEET 9; NORTH AND WEST ELEVATIONS: PROVIDE A DETAIL OF THE WROUGHT IRON TO THE STUD WALL CONNECTION. 11. PREVIOUS COMMENT 38: SHEET 9; LADDER DETAIL: PROVIDE A DETAIL OF THE LADDER TO WALL FACE CONNECTION AND THE LADDER TO THE TOP OF WALL CONNECTION. THE LADDER IS NO LONGER SHOWN, BUT NOTE 9 INDICATES THERE IS A LADDER. CLARIFY. 12. PREVIOUS COMMENT 39: GENERAL: PROVIDE A CODE ANALYSIS ON THE DRAWINGS, INCLUDING OCCUPANT LOAD, MEANS OF EGRESS WIDTH REQUIREMENTS AND WIDTHS PROVIDED, EXIT ACCESS TRAVEL DISTANCES, AND PLUMBING FIXTURES REQUIRED AND PROVIDED (INCLUDING WATER CLOSETS, LAVATORIES, AND SERVICE SINK). 13. PREVIOUS NOTE 41: GENERAL: SECTION 3409.4 OF THE IBC REQUIRES ACCESSIBLE FEATURES AS LISTED. ADDRESS THESE ISSUES ON THE DRAWINGS. 14. PREVIOUS COMMENT 42: GENERAL: ON THE DRAWINGS, PROVIDE A CONSTRUCTION COST BREAKDOWN, INDICATING HOW REQUIREMENTS OF SECTION 3409.7 OF THE IBC ARE MET. 15. PREVIOUS COMMENT 43: GENERAL: PROVIDE WALL FINISH SCHEDULE AND REFLECTED CEILING PLAN ON THE DRAWINGS. 16. PREVIOUS COMMENT 45: GENERAL: ALL DEFERRED SUBMITTALS MUST BE APPROVED IN WRITING BY RON BOOSE BEFORE THOSE SUBMITTALS WILL BE REVIEWED (RON.BOOSE@TUCSONAZ.GOV). 17. PREVIOUS COMMENT 46: GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. 18. GENERAL: ADD A NOTE ON THE DRAWINGS THAT PUBLIC ACCESS TO THE ROOF FROM THE NEW STAIR MUST BE PROHIBITED. 19. SHEET 8; ROOF PLAN: THE ROOF PLAN AS SHOWN IS NOT ACCURATE FOR THE EXISTING CONDITIONS. THERE IS A RIDGE LINE ON THE EXISTING EAST PORTION OF THE BUILDING, REQUIRING A CRICKET AT THE NEW ADDITION TO DRAIN WATER. REVISE. |
| 10/14/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 10/14/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 10/14/2011 | ERIC NEWCOMB | ZONING HC | REVIEW | Passed | |
| 10/14/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 10/17/2011 | CPIERCE1 | WWM | REVIEW | Needs Review | |
| 10/17/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |